8. Address Switch

8. Address Switch

8-1. Address Setting of the Remote Control Unit

The address can be set in order to prevent interference between remote controllers when two Sanyo indoor units are installed near each other. The address is nor- mally set to “A.” To set a different address, it is neces- sary to change the address on the second remote con- troller.

NOTE

Once changed, you cannot restore the original address setting of the air conditioner.

(1)Switch on the power source.

(2)Break the address-setting tab marked “A” on the second remote controller to change the address (Fig. 62). When the tab is removed, the address is automatically set to B (Fig. 63).

(3)Press and hold the remote controller ION button and 1 HR TIMER button. At the same time, press the ACL(reset) button. Use a thin object such as the tip of a pen to press the ACL button. When this has been done, “oP-1” (test run) appears, blinking, in the remote controller clock display area.

(4)Each time the 1 HR TIMER button is pressed, the display changes as shown below. Press this button 2 times to change the display to “oP-7” (address setting). (Fig. 64)

Test run mode

Selfdiagnostic mode

Adress setting mode

(5)“oP-7” has now been selected for address setting.

(6)Press the ON/OFF operation button on the remote controller. (Fig. 64) Check that the “beep”signal- received sound is heard from the second indoor unit (approximately 5 times). The sound you hear is the signal that the remote controller address has been changed.

(7)Finally press the remote controller ACL (reset) but- ton to cancel the blinking “oP-7” display.

(Fig. 64)

Changing of the second remote controller address is now completed.

Tab

Fig. 62

ACL button

Fig. 63

 

ON/OFF

ION

operation

button

button

 

8-1. Address Setting of the Remote Control Unit 1HR.

TIMER button

A

ACL

(Reset)

 

 

button

Fig. 64

24