Sanyo CH0971 service manual KHS1271, CH1271

Models: CH0971 CH1271

1 104
Download 104 pages 60.02 Kb
Page 25
Image 25
Manual background

Indoor Unit

: KHS1271

 

 

 

 

 

 

Outdoor Unit

: CH1271

 

 

 

 

 

 

Power Supply : 115V Single Phase 60Hz

 

 

 

 

 

< Heating Capacity >

 

 

 

 

 

 

 

RATING CAPACITY:

14,300 BTU/h

 

AIR FLOW RATE:

 

312 CFM

 

 

OUTDOOR

 

 

 

INDOOR

 

 

 

ENT. TEMP. oF (oC)

 

 

AMBIENT TEMP. oF (oC)

 

 

 

 

W.B.

 

60

65

70

75

80

 

 

 

 

 

(15.6)

(18.3)

(21.1)

(23.9)

(26.7)

 

 

0

(-17.8)

TH

8,010

8,000

7,980

7,960

7,930

 

 

 

 

 

 

 

 

 

 

 

 

3

(-16.1)

TH

8,280

8,270

8,250

8,230

8,200

 

 

 

 

 

 

 

 

 

 

 

 

8

(-13.3)

TH

8,930

8,910

8,890

8,870

8,840

 

 

 

 

 

 

 

 

 

 

 

 

13

(-10.6)

TH

9,600

9,580

9,560

9,530

9,500

 

 

 

 

 

 

 

 

 

 

 

 

18

(-7.8)

TH

10,330

10,310

10,290

10,260

10,220

 

 

 

 

 

 

 

 

 

 

 

 

23

(-5.0)

TH

11,100

11,080

11,050

11,020

10,980

 

 

 

 

 

 

 

 

 

 

 

 

28

(-2.2)

TH

11,900

11,870

11,840

11,800

11,760

 

 

 

 

 

 

 

 

 

 

 

 

33

(0.6)

TH

12,720

12,690

12,660

12,610

12,560

 

 

 

 

 

 

 

 

 

 

 

 

38

(3.3)

TH

13,530

13,500

13,460

13,410

13,360

 

 

 

 

 

 

 

 

 

 

 

 

43

(6.1)

TH

14,380

14,350

# 14,300

14,250

14,190

 

 

 

 

 

 

 

 

 

 

 

 

48

(8.9)

TH

15,240

15,200

15,150

15,090

15,020

 

 

 

 

 

 

 

 

 

 

 

 

53

(11.7)

TH

16,090

16,050

15,990

15,920

15,850

 

 

 

 

 

 

 

 

 

 

 

 

58

(14.4)

TH

16,910

16,850

16,790

16,720

16,640

 

 

 

 

 

 

 

 

 

 

 

 

63

(17.2)

TH

17,730

17,670

17,600

17,520

16,690

 

 

 

 

 

 

 

 

 

 

 

 

65

(18.3)

TH

18,040

17,980

17,910

17,480

16,620

TH : Total Heating Capacity (BTU/h)

NOTE

1.Rating conditions (#) : Indoor Unit Entering Air Temp. 70 °F (21.1 °C) D.B.

:Outdoor Ambient Temp. 47 °F (8.3 °C) D.B. / 43 °F (6.1 °C) W.B.

2.Above data does not take Defrost Operation, Overload Prevention Protection, and/or Cold Air Prevention Protection during heating operation into account. For this reason, the value may vary from the actual heating characteristics.

3.Above data represents the value when the operation frequency of a compressor is fixed.

25