How to Test Run the Air Conditioner

How to Test Run the Air Conditioner

After turning on power to the air conditioner, use the remote controller and follow the steps below to conduct the test run.

(1)Set the remote controller in Test Run mode. (Fig. 59a)

a)Press and hold the ION button.

b)Then press and hold the 1HR TIMER button.

c)At the same time, press the ACL (reset) button once. Use a pointed object such as the tip of a pen to press the ACL button.

After a few seconds, “ Fig. 59a ” appears and “oP-1” blinks in the remote controller display area.

(Fig. 59b)

d)Release the 1HR TIMER button.

e)Release the ION button.

(2)Start Cooling mode test run by pressing the ON/OFF operation button of the remote controller. (Fig. 59a)

This starts the fan producing uncooled forced air with the 4 indicator lamps (OPERATION lamp, TIMER lamp, QUIET lamp, and ION lamp) on the main unit blinking. (Fig. 59c)

After 3 minutes, the system shifts into cooling opera- tion, and cool air will start to be felt. Cool mode test run is unaffected by the room temperature.

(3)Press the ON/OFF operation button of the remote con- troller again to stop the test run. (Fig. 59a)

(4)Finally press the ACL (reset) button of the remote con- troller to release it from Test Run mode to return to nor- mal mode. (Fig. 59a)

Fig. 59c ” and “oP-1” will disappear from the remote con- troller display area.

NOTE

Troubleshooting:

In the event that the green “Operation Light” is blinking upon powering up the system, an error condition exists. In this case, refer to the self-diagnostics procedure on the

inside of the front cover.

IMPORTANT

After the test run is completed, be sure to press the ACL (reset) button to return to normal mode. The air conditioner will not operate correctly if this is not done.

 

ON/OFF

ION

operation

button

button

 

Manual background 1HR.

TIMER button

A

ACL

(Reset)

 

 

button

Fig. 59a

Fig. 59b

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background OPERATION lamp

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background TIMER lamp

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background QUIET lamp

Manual backgroundManual background ION lamp

Fig. 59c

21

Page 100
Image 100
Sanyo CH1271, CH0971 service manual How to Test Run the Air Conditioner, a b