Sanyo CH1271 service manual Heating Capacity, KHS0971, CH0971

Models: CH0971 CH1271

1 104
Download 104 pages 60.02 Kb
Page 24
Image 24
5-4. Heating Capacity

5-4. Heating Capacity

Indoor Unit

: KHS0971

 

 

 

 

 

 

Outdoor Unit

: CH0971

 

 

 

 

 

 

Power Supply : 115V Single Phase 60Hz

 

 

 

 

 

< Heating Capacity >

 

 

 

 

 

 

 

RATING CAPACITY:

12,200 BTU/h

 

AIR FLOW RATE:

 

312 CFM

 

 

OUTDOOR

 

 

 

INDOOR

 

 

 

ENT. TEMP. oF (oC)

 

 

AMBIENT TEMP. oF (oC)

 

 

 

 

W.B.

 

60

65

70

75

80

 

 

 

 

 

(15.6)

(18.3)

(21.1)

(23.9)

(26.7)

 

 

0

(-17.8)

TH

6,910

6,900

6,890

6,870

6,840

 

 

 

 

 

 

 

 

 

 

 

 

3

(-16.1)

TH

7,140

7,130

7,110

7,090

7,070

 

 

 

 

 

 

 

 

 

 

 

 

8

(-13.3)

TH

7,680

7,670

7,660

7,630

7,610

 

 

 

 

 

 

 

 

 

 

 

 

13

(-10.6)

TH

8,250

8,230

8,220

8,190

8,170

 

 

 

 

 

 

 

 

 

 

 

 

18

(-7.8)

TH

8,860

8,850

8,830

8,810

8,780

 

 

 

 

 

 

 

 

 

 

 

 

23

(-5.0)

TH

9,510

9,490

9,470

9,450

9,420

 

 

 

 

 

 

 

 

 

 

 

 

28

(-2.2)

TH

10,180

10,160

10,140

10,110

10,080

 

 

 

 

 

 

 

 

 

 

 

 

33

(0.6)

TH

10,870

10,850

10,820

10,790

10,750

 

 

 

 

 

 

 

 

 

 

 

 

38

(3.3)

TH

11,540

11,520

11,490

11,460

11,420

 

 

 

 

 

 

 

 

 

 

 

 

43

(6.1)

TH

12,250

12,230

# 12,200

12,160

12,120

 

 

 

 

 

 

 

 

 

 

 

 

48

(8.9)

TH

12,970

12,940

12,910

12,870

12,820

 

 

 

 

 

 

 

 

 

 

 

 

53

(11.7)

TH

13,680

13,650

13,620

13,570

13,520

 

 

 

 

 

 

 

 

 

 

 

 

58

(14.4)

TH

14,360

14,330

14,290

14,240

14,180

 

 

 

 

 

 

 

 

 

 

 

 

63

(17.2)

TH

15,050

15,010

14,970

14,920

14,490

 

 

 

 

 

 

 

 

 

 

 

 

65

(18.3)

TH

15,310

15,280

15,230

15,180

14,470

TH : Total Heating Capacity (BTU/h)

NOTE

1.Rating conditions (#) : Indoor Unit Entering Air Temp. 70 °F (21.1 °C) D.B.

:Outdoor Ambient Temp. 47 °F (8.3 °C) D.B. / 43 °F (6.1 °C) W.B.

2.Above data does not take Defrost Operation, Overload Prevention Protection, and/or Cold Air Prevention Protection during heating operation into account. For this reason, the value may vary from the actual heating characteristics.

3.Above data represents the value when the operation frequency of a compressor is fixed.

24

Page 24
Image 24
Sanyo CH1271 service manual Heating Capacity, KHS0971, CH0971