Sanyo CH1271 General, Tools Required for Installation not supplied, Optional Copper Tubing Kit

Models: CH0971 CH1271

1 104
Download 104 pages 60.02 Kb
Page 82
Image 82
1. General

1. General

This booklet briefly outlines where and how to install the air conditioning system. Please read over the entire set of instructions for the indoor and outdoor units and make sure all accessory parts listed are with the system before beginning.

1-1. Tools Required for Installation (not supplied)

1.Standard screwdriver

2.Phillips head screwdriver

3.Knife or wire stripper

4.Tape measure

5.Carpenter’s level

1-2. Accessories Supplied with Unit Table 1

6.Sabre saw or key hole saw

7.Hacksaw

8.Core bits

9.Hammer

10.Drill

11.Tube cutter

12.Tube flaring tool

13.Torque wrench

14.Adjustable wrench

15.Reamer (for deburring)

Parts

Figure

Q’ty

Parts

Figure

Q’ty

Parts

Figure

Q’ty

Remote

 

 

Tapping screw

Truss-head

 

 

 

 

 

1

Phillips

10

Hex wrench*

 

1

control unit

 

 

 

 

 

 

5/32 ¥ 5/8" (4¥16 mm)

 

 

 

 

Remote control

 

1

Rawl plug

 

8

Clamp

 

1

unit holder

 

 

 

 

 

 

 

 

 

 

 

AAA alkaline

 

2

Drain hose

 

1

 

*Packed in the outdoor unit.

 

 

 

 

 

battery

 

adapter

 

 

 

 

 

 

 

 

 

 

 

Air clean filter

 

2

Cushion

 

4

 

 

 

 

rubber*

 

 

 

 

 

 

 

 

 

 

 

 

1-3. Optional Copper Tubing Kit

Copper tubing for connecting the outdoor unit to the indoor unit is available in kits which contain the narrow and wide tubing, fittings and insulation. Consult your nearest sales outlet or A/C workshop.

1-4. Type of Copper Tube and Insulation Material

2.Foamed polyethylene insulation for the specified copper tubes as required to precise length of tubing. Wall thickness of the insulation should be not less than 5/16" (8 mm).

3.Use insulated copper wire for field wiring. Wire size varies with the total length of wiring. Refer to 3-6. Wiring Instructions for details.

If you wish to purchase these materials separately from a local source, you will need:

CAUTION

1. Deoxidized annealed copper tube for refrigerant tub- ing as detailed in Table 2.

Cut each tube to the appropriate lengths 1' to 1'4" (30 cm to 40 cm) to dampen vibration between units.

Table 2

Model

Narrow Tube

Wide Tube

 

 

 

 

Outer Dia.

Thickness

Outer Dia.

Thickness

 

 

 

 

 

 

KHS0971/1271

1/4" (6.35 mm)

0.0314" (0.8 mm)

3/8" (9.52 mm)

0.0314" (0.8 mm)

 

 

 

 

 

Check local electrical codes and regulations before obtaining wire. Also, check any specified instructions or limitations.

3

Page 82
Image 82
Sanyo CH1271, CH0971 General, Tools Required for Installation not supplied, Accessories Supplied with Unit Table