Sanyo CH1271 service manual Cooling Capacity Low Ambient, KHS0971, CH0971

Models: CH0971 CH1271

1 104
Download 104 pages 60.02 Kb
Page 22
Image 22
5-3. Cooling Capacity (Low Ambient)

5-3. Cooling Capacity (Low Ambient)

Indoor Unit

: KHS0971

 

 

 

 

 

 

 

 

 

 

 

Outdoor Unit

: CH0971

 

 

 

 

 

 

 

 

 

 

 

Power Supply : 115V Single Phase 60Hz

 

 

 

 

 

 

 

 

 

< Cooling Capacity (Low Ambient) >

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATING CAPACITY:

9,000 BTU/h

 

AIR FLOW RATE:

 

282 CFM

 

 

INDOOR

 

 

 

 

 

OUTDOOR

 

 

 

 

 

ENT. TEMP. oF (oC)

 

 

 

 

AMBIENT TEMP. oF (oC)

 

 

 

 

W.B.

D.B.

 

 

0

5

15

25

 

35

45

55

 

 

 

 

 

 

 

(-17.8)

(-15.0)

(-9.4)

(-3.9)

 

(1.7)

(7.2)

(12.8)

 

 

 

 

 

TC

 

7,310

7,300

7,350

7,380

 

7,390

7,370

7,310

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72 (22.2)

SHC

 

6,050

6,050

6,050

6,100

 

6,100

6,050

6,050

 

 

59

76 (24.4)

SHC

 

6,980

6,980

7,030

7,030

 

7,030

7,030

6,980

 

 

(15.0)

80

(26.7)

SHC

 

7,310

7,300

7,350

7,380

 

7,390

7,370

7,310

 

 

 

84 (28.9)

SHC

 

7,310

7,300

7,350

7,380

 

7,390

7,370

7,310

 

 

 

88 (31.1)

SHC

 

7,310

7,300

7,350

7,380

 

7,390

7,370

7,310

 

 

 

 

 

TC

 

7,330

7,330

7,420

7,490

 

7,530

7,540

7,490

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72 (22.2)

SHC

 

4,840

4,840

4,840

4,890

 

4,890

4,890

4,890

 

 

63

76 (24.4)

SHC

 

5,770

5,770

5,830

5,880

 

5,880

5,880

5,880

 

 

(17.2)

80

(26.7)

SHC

 

6,810

6,810

6,810

6,870

 

6,870

6,870

6,870

 

 

 

84 (28.9)

SHC

 

7,330

7,330

7,420

7,490

 

7,530

7,540

7,490

 

 

 

88 (31.1)

SHC

 

7,330

7,330

7,420

7,490

 

7,530

7,540

7,490

 

 

 

 

 

TC

 

7,290

7,300

7,450

7,560

 

7,640

7,680

7,660

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72 (22.2)

SHC

 

3,580

3,580

3,630

3,690

 

3,740

3,740

3,740

 

 

67

76 (24.4)

SHC

 

4,560

4,560

4,620

4,670

 

4,670

4,730

4,670

 

 

(19.4)

80 (26.7)

SHC

 

5,550

5,550

5,610

5,660

 

5,720

5,720

5,720

 

 

 

84 (28.9)

SHC

 

6,540

6,540

6,590

6,650

 

6,650

6,650

6,650

 

 

 

88 (31.1)

SHC

 

7,290

7,300

7,450

7,560

 

7,640

7,640

7,640

 

 

 

 

 

TC

 

7,170

7,190

7,400

7,570

 

7,700

7,780

7,780

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72 (22.2)

SHC

 

2,320

2,320

2,370

2,420

 

2,480

2,530

2,530

 

 

71

76 (24.4)

SHC

 

3,250

3,250

3,360

3,410

 

3,470

3,470

3,470

 

 

(21.7)

80 (26.7)

SHC

 

4,290

4,290

4,350

4,400

 

4,450

4,510

4,510

 

 

 

84 (28.9)

SHC

 

5,220

5,220

5,330

5,390

 

5,440

5,440

5,440

 

 

 

88 (31.1)

SHC

 

6,210

6,210

6,270

6,320

 

6,370

6,430

6,430

 

 

 

 

 

TC

 

6,980

7,010

7,300

7,530

 

7,710

7,820

7,850

 

 

75

 

 

 

 

 

 

 

 

 

 

 

 

 

76 (24.4)

SHC

 

2,040

2,040

2,150

2,210

 

2,260

2,320

2,320

 

 

(23.9)

80 (26.7)

SHC

 

3,030

3,030

3,140

3,190

 

3,250

3,300

3,300

 

 

 

84 (28.9)

SHC

 

4,020

4,020

4,130

4,180

 

4,240

4,240

4,290

 

 

 

88 (31.1)

SHC

 

4,950

4,950

5,060

5,110

 

5,170

5,220

5,220

 

 

 

 

 

TC :

Total Cooling Capacity (BTU/h)

SHC : Sensible Heat Capacity (BTU/h)

NOTE

1.Above data does not take Freeze Prevention Protection during cooling operation into account. For this reason, the value may vary from the actual cooling characteristics.

2.Above data represents the value when the operation frequency of a compressor is fixed.

22