Sanyo DE Flue & stack connection, Flue flange dimensional data, Typical steel stack

Models: DE

1 50
Download 50 pages 27.2 Kb
Page 21
Image 21
Flue & stack connection

ENVIRONMENTALLY FRIENDLY TECHNOLOGY

Flue & stack connection

The flue and stack must be heat-insulated and provided with a damper and a condensate drain.

The flue should never be connected to an incinerator stack.

Locate the top end of the smoke stack at a sufficiently large distance away from the cooling tower.

If the same stack is used for discharging exhaust from two systems, the back flow of exhaust should be prevented from going into the one which is out of operation.

Provide a draft regulator if fluctuations in static pressure are expected inside the flue.

SUPER ABSORPTION

Flue flange dimensional data

Figure 30. Flue flange

K

B C D E F G H

A

Typical steel stack

As illustrated, the steel stack should be lined on the interior surface as a protection from corrosion due to exhaust gas.

Compliance with local regulation

Municipal codes in many areas may regulate large capacity chillers con- suming oil or gas as fuel.

Such regulations should be strictly abided by.

Figure 29. Typical flue and stack installation

NOTES :

Please design the draft pressure at flue flange of the chiller/heaters with negative pressure 0 thru -29.4Pa (0 thru -3mmH2O).

Draft regulator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flue(Insulated)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Field supply

Damper

Internal lining

Stack

 

 

Q

S

 

R

 

 

P

 

M

ø T hole

 

N

 

 

 

 

A

 

M

6

 

 

L

NOTE :

1.Field supply

2.Steel material

Table 7.

Dimensional data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

 

 

 

 

 

 

 

Dimensions (mm)

 

 

 

 

 

 

 

 

 

No.

A

B

C

D

E

F

G

H

K

L

M

N

P

Q

R

S

T

 

 

DE-11

15

110

110

110

---

---

---

---

345

360

38

130

130

---

275

290

15

 

Condensate drain

Fire-proof mortar

Condensate drain

DE-12

15

110

110

110

---

---

---

---

345

360

38

130

130

---

275

290

15

DE-13

15

110

110

110

---

---

---

---

345

360

38

130

130

---

275

290

15

DE-14

15

110

110

110

---

---

---

---

345

360

38

130

130

---

275

290

15

DE-21

15

120

120

---

---

---

---

---

375

390

38

120

120

---

375

390

15

DE-22

15

120

120

---

---

---

---

---

375

390

38

120

120

---

375

390

15

DE-23

15

120

120

---

---

---

---

---

375

390

38

120

120

---

375

390

15

DE-24

15

120

120

---

---

---

---

---

375

390

38

120

120

---

375

390

15

DE-31

20

100.5

100.5

100.5

---

---

---

---

422

442

38

117

118

---

372

392

15

DE-32

20

100.5

100.5

100.5

---

---

---

---

422

442

38

117

118

---

372

392

15

DE-41

15

115

115

115

---

---

---

---

475

490

38

120

120

---

375

390

15

DE-42

15

115

115

115

---

---

---

---

475

490

38

120

120

---

375

390

15

DE-51

15

139.5

139.5

139.5

---

---

---

---

573

588

38

137

137

--

426

441

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DE-52

15

139.5

139.5

139.5

---

---

---

---

573

588

38

137

137

--

426

441

15

DE-53

15

139.5

139.5

139.5

---

---

---

---

573

588

38

137

137

--

426

441

15

DE-61

15

113

113

113

113

113

---

---

693

708

38

114.5

114.5

114.5

473

488

15

DE-62

15

113

113

113

113

113

---

---

693

708

38

114.5

114.5

114.5

473

488

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DE-63

15

113

113

113

113

113

---

---

693

708

38

114.5

114.5

114.5

473

488

15

DE-71

15

119

120

120

120

120

120

120

973

988

38

113

113

112

464

479

19

DE-72

15

119

120

120

120

120

120

120

973

988

38

113

113

112

464

479

19

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DE-73

15

119

120

120

120

120

120

120

973

988

38

113

113

112

464

479

19

DE-81

15

119

120

120

120

120

120

120

973

988

38

113

113

112

464

479

19

DE-82

15

119

120

120

120

120

120

120

973

988

38

113

113

112

464

479

19

38

39

Page 21
Image 21
Sanyo DE Flue & stack connection, Flue flange dimensional data, Typical steel stack, Compliance with local regulation