Sanyo Foundation dimensional data DE, Control panel DE, H Generator temp 149 . 9 C

Models: DE

1 50
Download 50 pages 27.2 Kb
Page 18
Image 18
Foundation dimensional data (DE)

ENVIRONMENTALLY FRIENDLY TECHNOLOGY

Foundation dimensional data (DE)

Figure 21. Details of weld

Nut

 

 

Weld

Washer

80

Base

A

A=150mm and more

Figure 23. DE-13 Thru DE-63

Figure 22. DE-11 Thru DE-12

C

 

G

 

 

 

 

AA

 

F

E

 

 

 

 

 

P

 

 

 

G

 

K

H

 

 

 

M

L

N Control panel (DE)

G

S

AA

 

BB

 

CC

 

 

Q

T

U

R

H

SUPER ABSORPTION

Control panel (DE)

 

SETTING STOP RUN

COOLING

BURNER

H Generator temp 149 . 9 ° C

CHILLER

HEATING

ALARM

REF PUMP

BUZZER STOP

 

 

#1 ABS PUMP

MODE

 

 

 

 

 

#2 ABS PUMP

OPERATION

REMOTE

 

PURGE PUMP

 

 

 

BURNER BLOWER

STOP

LOCAL

CAB

 

G

F

E

D

D

AA

AA

 

T

P

Q

G

 

Figure 24. DE-71 Thru DE-82

G

D

C

G

 

 

D

 

 

 

 

 

 

H

Table 6. Indication lamp

symbol

Name

Lamp color

K

H

 

J

 

 

S

M L

 

BB

CC

R

 

 

N

 

 

A

 

B

U L K E

AA

Manual backgroundCC

BB

G

AA

P

Q

 

S

R M

J

 

T

F

Running(Operation) indication lamp

Red

Stop indication lamp

Green

 

 

Alarm indication lamp

Orange

 

 

Bunner combustion indication lamp

Red

 

 

Cooling / Heating indication lamp

Orange

 

 

Remote / Local select button with lamp

Red

NOTES :

1.

Shaded area indicates the base of absorption chiller/heaters.

2.

A reasonably level concrete foundation must be provided on which

 

to mount the chiller.

H

A

J

B

N

Mode select button with lamp

Red

Data display

LCD

3.

Provide a floor drainage ditch around foundation of the chiller.

4.

If foundation anchoring is required, supply anchor bolts and nuts. Fix

 

anchor bolts on the foundation prior to chiller installation and as per

 

detail of weld (Figure 21). Washers are supplied with the chiller.

Table 5. Dimensional data

5.For direct-fired (DE) chiller/heaters, provide support for the burner and gas train.

6.Unit must be level before startup. See leveling information in ” Instal lation and Application Data ” section of this catalog.

Figure 25. Control panel

DE--11 thru DE--42

500

DE--51 thru DE--82

600

Model

 

Weight (kg)

 

 

 

 

 

 

 

 

 

Dimensions (mm)

 

 

 

 

 

 

 

 

No.

Oper.

AA

BB

CC

A

B

C

D

E

F

G

H

I

K

L

M

N

P

Q

R

S

T

U

DE-11

4,900

1,600

900

800

865

850

1,896

--

800

1,100

150

175

350

150

550

850

175

350

150

650

150

900

1,855

DE-12

5,200

1,700

1,000

800

665

1,050

1,896

--

800

1,100

150

175

350

150

550

850

175

350

150

650

150

900

1,855

DE-13

6,000

2,100

1,200

900

1,000

1,100

2,916

--

800

1,100

150

175

350

150

600

900

175

350

150

700

150

900

--

DE-14

6,800

2,300

1,300

900

800

1,300

2,916

--

800

1,100

150

175

350

300

600

900

175

350

150

700

150

900

--

DE-21

8,000

2,700

1,400

1,200

1,000

1,350

2,916

--

1,000

1,300

150

175

350

185

650

950

175

350

150

750

150

1,100

--

DE-22

8,500

2,800

1,600

1,300

800

1,550

2,916

--

1,000

1,300

150

175

350

185

650

950

175

350

150

750

150

1,100

--

DE-23

9,800

3,300

1,700

1,500

1,400

1,850

3,936

--

1,000

1,300

150

175

350

205

650

950

175

350

150

750

150

1,100

--

DE-24

10,400

3,500

1,900

1,500

1,200

2,050

3,936

--

1,000

1,300

150

175

350

205

650

950

175

350

150

750

150

1,100

--

DE-31

12,800

4,400

2,200

1,800

1,400

1,750

3,886

--

1,100

1,400

150

200

400

200

700

1,000

200

400

200

800

200

1,200

--

DE-32

13,500

4,500

2,400

2,100

1,200

1,950

3,886

--

1,100

1,400

150

200

400

200

700

1,000

200

400

200

800

200

1,200

--

DE-41

15,800

5,400

2,700

2,300

1,030

2,050

3,886

--

1,150

1,450

150

200

400

245

800

1,100

200

400

200

900

200

1,250

--

DE-42

16,600

5,500

3,000

2,600

830

2,250

3,886

--

1,150

1,450

150

200

400

245

800

1,100

200

400

200

900

200

1,250

--

DE-51

22,200

8,000

3,300

2,900

1,130

2,000

3,966

130

1,600

1,960

180

190

510

120

900

1,260

230

460

200

1,000

250

1,700

--

DE-52

24,000

8,600

3,600

3,200

1,130

2,200

4,508

130

1,600

1,960

180

190

510

120

900

1,260

230

460

200

1,000

250

1,700

--

DE-53

25,700

9,200

3,900

3,400

1,130

2,400

5,006

130

1,600

1,960

180

190

510

120

900

1,260

230

460

200

1,000

250

1,700

--

DE-61

31,90011,300

4,900

4,400

1,398

2,400

4,468

140

1,800

2,160

180

310

560

120

1,000

1,360

280

560

300

1,100

300

1,900

--

DE-62

34,40012,100

5,400

4,800

1,398

2,700

4,966

140

1,800

2,160

180

210

560

120

1,000

1,360

280

560

300

1,100

300

1,900

--

DE-63

37,10013,000

5,800

5,300

1,398

3,000

5,490

140

1,800

2,160

180

210

560

120

1,000

1,360

280

560

300

1,100

300

1,900

--

DE-71

45,10015,900

6,900

6,400

70

3,100

4,566

140

2,200

2,560

180

210

560

220

1,200

1,560

280

560

300

1,300

300

2,300

--

DE-72

48,50017,000

7,600

6,900

70

3,400

5,091

140

2,200

2,560

180

210

560

220

1,200

1,560

280

560

300

1,300

300

2,300

--

DE-73

51,50018,000

8,100

7,400

70

3,700

5,594

140

2,200

2,560

180

210

560

220

1,200

1,560

280

560

300

1,300

300

2,300

--

DE-81

56,10019,500

8,900

8,200

70

3,700

5,091

140

2,400

2,760

180

210

560

200

1,400

1,760

280

560

300

1,500

300

2,500

--

DE-82

59,10020,600

9,300

8,600

70

3,900

5,591

140

2,400

2,760

180

210

560

200

1,400

1,760

280

560

300

1,500

300

2,500

--

1600

120 70

Power supply ø 33

Remote control ø 27

30

300

12070

80

Power supply ø 52 Remote control ø 27

30

300

32

33

Page 18
Image 18
Sanyo Foundation dimensional data DE, Control panel DE, H Generator temp 149 . 9 C, Environmentally Friendly Technology