ROUTINE MAINTENANCE
WARNING
Always disconnect the power supply to the unit prior to any repair or maintenance of the unit in
order to prevent electric shock or injury.
Ensure you do not inhale or consume medication or aerosols from around the unit at the time of maintenance. These may be harmful to your health.
CAUTION
Always wear dry gloves to protect hands at the time of maintenance. Failure to wear gloves may result in injury from edges and corners.
Cleaning of cabinet
㩵Clean the unit once a month. Regular cleaning keeps the unit looking new.
㩵Use a dry cloth to wipe off small amounts of dirt on the outside and inside of the unit and all accessories. If the outside panels are dirty, clean them with a diluted neutral dishwashing detergent. (Undiluted detergent can damage the plastic components. For the dilution, refer to the instruction of the
detergent.) After the cleaning with the diluted detergent, always wipe it off with a wet cloth. Then wipe off the cabinet or accessories with a dry cloth.
㩵Never pour water onto or into the unit. Doing so can damage the electric insulation and cause failure.
㩵The compressor and other mechanical parts are completely sealed. This unit requires absolutely no lubrication.
Cleaning of evaporating tray
The evaporating tray is installed on the back on of the unit.
1.Remove the tray fixture under the evaporating tray by unscrewing 4 screws and the evaporating tray is free. (Fig. 1)
2.Wash away any accumulated dirt in the evaporating tray.
3.Fix the evaporating tray with the tray fixture and 4 screws.
Clean the evaporating tray once a month.
Evaporating tray
Tray fixture
Screw
Fig. 1
23