OUTPUT TERMINALS

WARNING OUT Terminal

œTheWARNING OUT terminal output becomes 0 V (Low) in accordance with the (WARNING OUT/CONTROL SET) menu.

WARNING OUT Terminal Output Setting

1PressMENUthebutton to display the MAIN MENU.

2TurnJOGthedial to select the“4.WARNING OUT/CONTR. SET” line, then turn the SHUTTLE ring clockwise.

øThe (WARNING OUT/CONTROL SET) menu appears.

<WARNING@OUT@SET>SET@UP

ALARM@@@@@@@@@@@@Y

NON@REC@@@@@@@@@@N

MECHA.PROBLEM@@@@Y

VIDEO@LOSS@@@@@@@Y

CLOG@DETECT.@@@@@Y

<CONTROL@SET>

EJECT@MODE@@@@@@@EJECT1

OPERATION@@@@@@@@SLAVE

3 TurnSHUTTLEthe ring clockwise.

4TurnJOGthedial to select the desired mode, then turn theSHUTTLE ring clockwise.

SET UP . . . . Set each itemALL Y . . . . . . To set all items to“Y”

ALL N . . . . . . To set all items to “N”

œ If using“SET UP”thesetting, continue with steps

5to7.

5TurnJOGthedial until the item for warning output is highlighted, then turn theSHUTTLE ring clockwise.

6TurnJOGthedial to set“Y” (warning is given) or “N” (warning is not given), then turn the SHUTTLE ring clockwise.

ALARM. . . . . . . . . . . The output becomes 0 V and “A” appears on the digital display during alarm recording

NON REC . . . . . . . . The output becomes 0 V and “N” appears on the digital display if the VCR enters a mode other than recording (i.e. recording pause, stop mode, etc.) during recording

MECHA. PROBLEM . . . The output becomes 0 V and “M” appears on the digital display when the tape stops or other problem with the internal mechanism

VIDEO LOSS . . . . . The output becomes 0 V and “V” appears on the digital display when there is no video signal

CLOG DETECT. . . . The output becomes 0 V and “C” appears on the digital display when the heads are dirty and the recording quality deteriorates

7 Repeat5stepsand6when setting ot

8 When finished,MENU EXITpressbutton. the

NOTES:

œThe“VIDEO LOSS” line does not appear if “VIDEO LOSS” is set to “N” in the (GENERAL SET) menu.

œThe“CLOG DETECT.” line does not appear if “CLOG DETECT.” is set to “N” in the (GENERAL SET) menu.

œDisplays on the digital displa other displays.

œCanceling warning displays and PressSTOPthebutton once.

The warning display disappears from the digital display.Press theSTOP button once more.

If “MECHA. PROBLEM” or “CLOG DETECT.” warnings are being output, then output stops.

œIf “NONtheREC”, “VIDEO LOSS” or “ALARM” warning is being output, the condition immediately before the warning output is restored and the output stops.

œIf the system has shut down

“MECHA. PROBLEM” warning, the output is canceled when the ALL RESET button is pressed.

English

47