ALARM RECORDING

Alarm Recording Reset Function

To stop the recording of an alarm, close the connection between theALARM RESET IN terminal and theCOM terminal during alarm recording.

Alarm Recording Counter Display

œDuring alarm“A”recording,will be flashing on the digital display.

Checking the Alarm Recordings Time

1PressMENUthebutton to display the MAIN MENU.

2TurnJOGthedial to select the“9.OTHERS” line, then turn the SHUTTLE ring clockwise.

øThe (OTHERS) menu appears.

<OTHERS>

*ALARM@LOG

*POWER@FAILURE/DEW

*TERMINAL@SET@@@@SET1

œ If a superimpose display is being displayed and

“ALARM COUNT” has been set to “Y” in the

 

(DISPLAY/SW OUT SET) menu, the number of alarm

 

recordings will flash on the monitor screen.

3 TurnJOGthedial to select the“ALARM LOG” line,

 

œThe maximum display number of alarm recordings is then turn the SHUTTLE ring clockwise.

“999”. At the next alarm recording the counter will

indicate “000”.

ø The (ALARM LOG) menu appears.

ø The number of alarm recordings, and the 10

œ When the (ALARM LOG) menu appears, press the

MENU RESET button to reset the alarm counter to

most recent alarm recording times are displayed.

“000” (all the data of the (ALARM LOG) menu is reset).

<ALARM@LOG>@@@@@@@@@010

@@@001@@@12-25@19:00

Connections to the ALARM IN Terminal

œAlarm input signal

Connect a make-contact (no theALARM IN and COM terminals.

@@@002@@@11-25@23:00

@@@003@@@10-25@15:00

@@@004@@@10-25@08:00

@@@005@@@10-25@06:00

@@@006@@@10-22@19:00

@@@007@@@10-22@17:15

voltage) switch@@@008@@@10-22@15:45between

@@@009@@@10-20@10:00

@@@010@@@10-18@12:00

œContinue turningJOG dial to displaythethe next (or previous) 10 alarm recording entries. When the number of alarm recording entries reaches 100, the older ones are erased as new ones are memorized.

4PressMENUtheEXIT button.

NOTE:

œIf MENUtheRESET button is pressed while the (ALARM LOG) menu is displayed, the displayed data is erased.“AL” will be erased from the digital display.

English

25