Unit 4: Printer Configuration
Switch 6: VR1 Potentiometer Adjustment mode
Selects the function adjusted by VR1. If DSW6 is Off, VR1 adjusts the pitch offset value over a range of +/- 3.75 mm. When DSW6 is On, VR1 adjusts the print darkness range.
DSW6 Mode
Off | Pitch Offset |
On | Print Darkness |
Switch 7: DATA Dump
When ON, the printer will print out the hex value for each character received. When OFF, the printer will accept and process the data stream in a normal fashion.
Configuration Switch
ON
OFF
1 2 3 4 5 6 7 8
DSW7 | Mode |
Off | DISABLED |
On | ENABLED |
Switch 8: Interface Board selection
This switch lets you choose whether to use the factory installed interface board connectors, or the
If not extended interface board is detected, switching DSW8 to Off will not affect the use of the
Configuration Switch
ON
OFF
1 2 3 4 5 6 7 8
| DSW8 | Mode |
|
|
|
|
|
| Off | Use extended |
|
|
| interface |
|
|
|
|
|
| On | Use internal |
|
|
| interface |
|
|
|
|
|
Configuration Switch
ON
OFF
CT4i Series Operator Manual |