Menu
Setting
Description
Range (Values)
Default
| Phase Labels | Specifies how phases are labelled | ABC, RST, XYZ, RYB, 123 | 123 | |
|
|
|
|
| |
| PF Symbol | LD (leading)/LG (lagging) | LD/LG, | LD/LG | |
|
|
|
|
| |
| Digit Group | Specifies symbols used to delimit | 1000.0 or 1,000.0 or 1000,0 | 1000,0 | |
| thousands and decimal place holder | ||||
|
|
|
| ||
|
|
|
|
| |
Format | Date Format | Specifies how dates are displayed | MM/DD/YYYY, DD/MM/YYYY, | MM/DD/ | |
YYYY/MM/DD | YYYY | ||||
|
| ||||
|
|
|
| ||
Show DST | Determines if DST is shown or not | Yes or No | Yes | ||
| |||||
|
|
|
|
| |
| Volts Decimal | Number of decimal places | 1. to 123 456 789,XXX | 1,XX | |
| displayed for voltages | ||||
|
|
|
| ||
|
|
|
|
| |
| Current Decimal | Number of decimal places | 1. to 123 456 789,XXX | 1,XXX | |
| displayed for currents | ||||
|
|
|
| ||
|
|
|
|
| |
| Power Decimal | Number of decimal places | 1. to 123 456 789,XXX | 1,XXX | |
| displayed for power measurements | ||||
|
|
|
| ||
|
|
|
|
| |
| Update Rate | Sets when the display updates (in | 1 to 6 | 1 | |
| seconds) | ||||
|
|
|
| ||
|
|
|
|
| |
| Contrast | Higher numbers are sharper | 0 to 9 | 7 | |
|
|
|
|
| |
|
| Specifies the time it takes (in |
| 300 (five | |
| Backlight Timeout | seconds) for the backlight to turn off | 0 to 7 200 (two hours) | ||
| minutes) | ||||
|
| (0 = the display stays lit indefinitely) |
| ||
|
|
|
| ||
|
|
|
|
| |
|
| Controls the minimum allowable | 0 (disabled) to 5 184 000 | 216 000 | |
| DMD Lock | time between consecutive demand | |||
Display | (60 days) | (25 days) | |||
| resets (in seconds) | ||||
|
|
| |||
|
|
|
| ||
TEST Mode TO | in TEST mode before switching back |
| 30 minutes | ||
|
| Defines how long the meter remains |
|
| |
|
| to NORM mode |
|
| |
|
|
|
|
| |
| Display Scale | Determines the scale applied to | 1 to 999 999 | 1000 | |
| displayed parameters | ||||
|
|
|
| ||
|
|
|
|
| |
|
| Specifies whether parameters are |
|
| |
| Scaling Mode | divided or multiplied by the scale | Multiply or Divide | Divide | |
|
| before being displayed |
|
| |
|
|
|
|
| |
| Delta Vectors | Specifies how vector diagrams are | System or Instrument | System | |
| displayed when in Delta mode | ||||
|
|
|
| ||
|
|
|
|
| |
| Modify Passwd | Modifies standard password | 0 to 999 999 999 | 0 | |
Security |
|
|
|
| |
Disable Security | Disables meter security | Disabled or Enabled | Enabled | ||
|
|
|
| ||
Web Config | Allow configuration via web server | Disabled or Enabled | Enabled | ||
| |||||
|
|
|
|
| |
| Ack Alarms | Sends a pulse to acknowledge | - | - | |
| alarms when selected | ||||
|
|
|
| ||
|
|
|
|
|
1A baud rate of 300 bps is only intended for paging applications.
2Serial number =
3Available on ION8800A and B meters only.
© 2007 Schneider Electric. All rights reserved. | 25 |