C1448, C1848, C2148W
Air and Water Cooled User Manual
Drains
All models require drain tubing to be attached to them. Air cooled models have a single ¾” FPT drain fitting in the back of the cabinet. Water cooled models have the same fitting plus an additional ½” FPT drain fitting in the back of the cabinet.
Install new tubing when replacing a prior ice machine, as the tubing will have been sized for the old model and might not be correct for this one.
1 Connect water supply to water inlet fittings.
Note: This NSF listed model has a 1"
2 Connect drain tubing to drain fittings.
3Route the drain tubing to building drain. Follow local codes for air gap.
Use rigid drain tubes and then route them separately – do not Tee into the bin’s drain or, if water cooled, Tee the condenser drain into the reservoir or bin drain.
Vent the reservoir drain. A vertical vent at the back of the drain, extended about 8 – 10” will allow the gravity drain to empty and also keep any surges during draining from discharging water.
Horizontal runs of drain tubing need a ¼” per fall per foot of run for proper draining.
Follow all applicable codes.
Water Inlet Connection
Potable Water Supply
Optional Water Filters
Floor Drain
Water Cooled
Condenser
Inlet
Reservoir
Drain
Water Cooled
Condenser
Drain
Water Supply and Drain Connections
November 2006
Page 11