Installation: Product Specifications
Location Limitations: The product is designed to be installed indoors, in a controlled environment. Air cooled models discharge very warm air into the room out the back. Space must be allowed at the left side and back for air intake and discharge. Water cooled models discharge warm water into the building’s drain. Space needs to be provided on both sides and above for service access.
Environmental Limitations
| Minimum | Maximum |
Air temperature | 50oF. | 100oF. |
Water | 40oF. | 100oF. |
temperature |
|
|
Water pressure | 20 psi | 80 psi |
|
|
|
Space Limitations
Note: Although the machine will function, ice capacity of air cooled machines will be significantly reduced with minimal clearance at the sides, back and top. Some space is recommended for service and maintenance purposes on all models.
6" of space at the sides and back are required for adequate operation. To get the most capacity, locate the machine away from heat producing appliances and heating ducts. Provide several feet of space to the left for maximum ice capacity.
Walls or other large machines near to the ice machine might also cause a reduction in ice capacity. One foot behind and two feet above will be required to make rated capacity.
Airflow is in the front, in the left side, out the back (as viewed from the front).
Power supply – acceptable voltage ranges
| Minimum | Maximum | |
198 volts | 253 volts | ||
model | |||
|
| ||
|
|
|
Warranty Information
The warranty statement for this product is provided separately from this manual. Refer to it for applicable coverage. In general warranty covers defects in material or workmanship. It does not cover maintenance, corrections to installations, or situations when the machine is operated in circumstances that exceed the limitations printed above.