HOW TO CONVERT THE RANGE FOR USE WiTH LP GAS
WARNING: Do not remove the pressure regulator from the range. l
Step t
Convert The Pressure Regulator
For LP Gas
1.Remove the cooktop and locate the pressure regu- lator at right rear of the range1
2.Determine which figure, A, B, or C, is appropriate for your regulator type.
If it is regulator A:
1. Use a coin to remove the cap from the pressure regulator.
G.s NAT |
| LP | |
Ffow |
|
| |
Inlo | _ | OR | |
R_nge | |||
|
|
,_ | ROTATE OPEN |
2, Turn the cap over and engage it in the slots, LP should now be visible on the top of the cap..
If it is regulator B:
1. Unscrew the
2.Carefully pry the protective plastic cap off the threaded metal cap,, Gently pull the plastic washer off the other threads.
3.Replace the plastic cap onto the threaded end dis- playing the gas type you desire. Press the plastic washer onto the remaining threads.
4.Reinsert the cap assembly into the regulator., Do not overtighten, but ensure the seating of the washer.,
If it is regulator C:
1.Remove cap and forcibly snap out plastic plunger from bottom of cap.
2.Turn plunger over and forcibly snap back in original location. Note: Plunger must snap into position; the gas type you are converting to must be visible on lower side of plunger.
3.Reinsert the assembly into the regulator.
Step 2
Convert Surface Burners For LP Gas
I. Lift cooktop,
NATDb oR
},%° T " oo.o',o_.o.o,'p,o'oo". oop".
except for uonversion | _.__ |
Frow NAT | OR |
RangInto _
Do not remove this
ROTATE OPEN
C
2.Lift burner assemblies straight up and set aside to gain access to surface burner spuds,
3.With a 5/16" wrench, remove each of the four brass spuds on the surface burner gas inlet tubes and replace them with the
4.Replace the burner assemblies,
5.Keep the natural gas spuds with your range so yoHt have them if you move or get a natural gas
(continued next page)
11