1 Press the REC button.

Record pause mode is entered.

The REC button does not light.

2 Begin playback on the stereo system con- nected to this portable MD.

To enable the record level to be set.

3 Move the right shuttle switch to 5 or 4 to adjust the recording level.

Analogue recording

Adjust the recording level so that the maximum sound volume from the source makes the read- ing swing somewhere between –4 dB and 0 dB.

Level meter indicator

0dB 4dB

Digital recording

You can adjust the level in 1 dB increments within the range of +12 - –12dB.

+12 - –12dB

Once you adjust the digital recording level, the setting remains even after the recording stops. (For cancellation instructions, see page 38.)

4 Press the PAUSE button on the stereo sys- tem to enter the playback pause mode at the point you wish to start recording.

Here you can select the track to be recorded.

5 Press the 06 button to start the MiniDisc unit recording.

6 Begin playback on the stereo system, the output will be recorded.

Notes:

Changing the volume level whilst recording does not af- fect the recording.

You cannot adjust the bass level whilst recording.

Basic Operation – Recording –