Sharp XGPH80XN Removing and Installing the Lamp Unit, Remove the lamp unit cover, Lamp unit

Models: XGPH80XN XG-PH80W-N XG-PH80X-N

1 84
Download 84 pages 43 Kb
Page 71
Image 71

Removing and Installing the Lamp Unit

Info

Do not touch the glass surface of the lamp unit or the inside of the projector.

To avoid injury to yourself and damage to the lamp, make sure you carefully follow the steps below.

Do not loosen other screws except for the lamp unit cover and lamp unit.

Warning!

Do not remove the lamp unit from the projector right after use. The lamp and parts around the lamp will be very hot and may cause burns or injury.

Optional

Lamp unit

accessory

AN-PH80LP

 

1

2

Press STANDBY/ON on the projector or on the remote control to put the projector into Standby mode.

Switch the MAIN POWER switch on the projector to “OFF” and then disconnect the power cord.

Unplug the power cord from the AC socket.

Leave the lamp until it has fully cooled down (about 1 hour).

STANDBY/ON button

MAIN POWER switch

AC socket

3 Remove the lamp unit cover.

• Loosen the user service screw (1) that secures the lamp unit cover. Remove the lamp unit cover (2).

User service screw (for lamp unit cover)

4 Remove the lamp unit.

• Loosen the securing screws (two for each lamp) from the lamp unit. Hold the lamp unit by the handle and pull it in the direction of the arrow. At this time, keep the lamp unit horizontal and do not tilt it.

Appendix

67

Page 71
Image 71
Sharp XGPH80XN, XG-PH80W-N, XG-PH80X-N appendix Removing and Installing the Lamp Unit, Remove the lamp unit cover, Lamp unit