Siemens optiPoint 500 Analog Adapters, Option Adapters and Ports, RJ11, Functions

Models: 500

1 120
Download 120 pages 55.13 Kb
Page 54
Image 54
optiPoint 500 Analog Adapters

Option Adapters and Ports

optiPoint 500 Analog Adapters

5.3optiPoint 500 Analog Adapters

This type of adapter is used for connecting an analog terminal (e.g. telephone, group 3 fax, mo- dem, cordless telephone) to the system telephone.

A local power supply unit is required when using an analog adapter.

 

>Only DTMF terminals can be connected to an analog adapter

 

 

(no dial pulsing).

 

 

 

 

 

MW6/6

 

 

 

 

 

Pin 1

Pin 2

Pin 3

Pin 4

Pin 5

Pin 6

NC

NC

TIP +

RING

NC

NC

 

 

 

 

 

 

 

6

5 4

3

2

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RJ11

Functions

The connected analog equipment can use this interface to send and receive calls indepen- dently of the voice call status of the basic device, provided that a B channel is available.

During adapter initialization, country-specific information (such as impedance and flash signal duration) is loaded.

You can connect an external ringer (secondary bell for the telephone) via TA a/b.

The AC bell, which can be connected instead of an analog terminal, is treated like a "phys- ical device" (source) and receives signals from the system.

Administration is in MULAP form.

5-8

P31003-E8400-A100-3-7620

Service Manual

Page 54
Image 54