Siemens 500 service manual Option Adapters and Ports, Analog Interface

Models: 500

1 120
Download 120 pages 55.13 Kb
Page 55
Image 55

Option Adapters and Ports

optiPoint 500 Analog Adapters

Analog Interface

Standard analog interface for

analog telephones

cordless telephones

fax machines or other

analog equipment with an analog interface

Supply current 30 mA

Busy signal if both B-channel lines are busy

Ring sequence: 2.2

Supports only DTMF with flash

No ground signaling allowed

MW 6/4 (RJ11/8) connector

The adapter does not support the following functions:

Voice mail servers with analog interface

Message waiting LED

Dictation equipment

Speaker

Announcement device (such as start/stop)

Screen keys (PC connected to RS232) and

A, B, C, D keys on the enhanced telephone.

Telephone active:

Handset off-hook, speakerphone mode, open listening, headset

 

 

active

Ringer on:

Contact opens and closes with the ring cadence

P31003-E8400-A100-3-7620

5-9

Service Manual

Page 55
Image 55
Siemens 500 Option Adapters and Ports, Analog Interface, The adapter does not support the following functions