Siemens 5890 manual Snmp IP Filter, Click Add IP Range

Models: 5890

1 102
Download 102 pages 39.19 Kb
Page 72
Image 72

SIEMENS 5890 DSL Router

Chapter 6 Security Setup

User’s Guide

SNMP

 

 

5.In Trap Enable, select Enable or Disable. SNMP agents also have the ability to send (unrequested) messages to SNMP managers; these messages are called traps and notify the SNMP managers that an event has happened on the system.

6.If you enabled Trap Enable, in Trap Manager[1-4]specify the IP address for a node that will receive a Trap event from the router. You can specify up to four trap managers.

7.Click Apply.

8.Configure SNMP IP Filter and SNMP Password.

SNMP IP Filter

Activating an IP Filter range will limit SNMP requests to only those that originate from the designated addresses or LAN. To activate IP filtering:

1.Click SNMP IP Filter from the SNMP Configuration page. This displays the SNMP IP Filter Configuration page. The current IP filter ranges are displayed in the IP Addresses.

2.In Start IP Range, enter the first IP address in the range to be filtered.

3.In End IP Range, enter the last IP address in the range to be filtered.

4.Optionally click LAN.

5.Click Add IP Range.

SIEMENS

66

Page 72
Image 72