SMC Networks M8501 manual 2. Fault Symptom Codes, Message

Models: M8501

1 78
Download 78 pages 42.86 Kb
Page 64
Image 64
Manual background

TroubleshootingFault Symptom Codes (FSCs)

Table 6-2. Fault Symptom Codes

Message

FSC

ERP

 

Picker Jammed 11

310B

C, G

The picker jammed during a drive fetch

 

 

 

operation.

Picker Jammed on

310F

C, G

The picker jammed on a stow operation.

Stow

 

 

 

Picker retries

3111

C, G

Picker retries exceeded during a pass-

Exceeded 1

 

 

thru fetch operation.

Picker Retries

3113

C, G

Picker retries exceeded during a bin stow

Exceeded 3

 

 

operation.

Picker Retraction

3115

C, G

The picker did not retract during a bin

Error

 

 

check operation.

Shuttle Jammed

3200

C, G

The shuttle could not reach the target

 

 

 

location.

Rotary Jammed

3300

C, G

The rotary track could not reach the target

 

 

 

location.

Shuttle on Wrong Side

3301

C, G

The zone indicators show that the shuttle

Of The Rotary

 

 

is backwards on the rotary track during

 

 

 

power-up initialization.

Pass through Elevator

3400

C, G

The pass-thru shuttle could not reach the

Jammed

 

 

target location.

Vertical Elevator

3500

C, G

The vertical elevator could not reach the

Jammed

 

 

target location

All Slots Empty

5011

F

There are no cartridges installed in any of

 

 

 

the reserved cleaning slots.

DLT Already Loaded

5014

F

The cleaning operation failed because the

 

 

 

drive already has a cartridge inserted.

Expired Clean'g Cart

5015

F

The cleaning operation failed due to an

 

 

 

expired cleaning cartridge.

Not a Clean'g Cart

5016

F

The cleaning operation failed because the

 

 

 

loaded cartridge is not a cleaning

 

 

 

cartridge.

DLT Time-out Error

5035

C, D, G The cleaning operation failed because the

 

 

 

drive timed out.

move Command Fail

503B

F

A front panel move operation failed.

Clean Operation

503C

F

The cleaning operation failed because the

Time-out

 

 

drive timed out.

Drive Status Fail

503D

F

The cleaning operation failed because the

 

 

 

ACL could not retrieve drive status.

Command response

7001

D, G

A command response was received from

from unexpected

 

 

a task to which a command had not been

source

 

 

sent.

 

 

 

 

M8501 and M8502 ACL Tape Drive Installation and User’s Guide 529972-001

6-8