SMC Networks M8501 manual 2. Fault Symptom Codes, Message

Models: M8501

1 78
Download 78 pages 42.86 Kb
Page 65
Image 65
Manual background

TroubleshootingFault Symptom Codes (FSCs)

Table 6-2. Fault Symptom Codes

Message

FSC

ERP

 

Control command

7002

D, G

A command response opcode from the

execution failed

 

 

Control task was not anticipated or is un-

 

 

 

identifiable.

Control response not

7003

D,G

A command response was received from

matched to a known

 

 

the Control task, but the original

command

 

 

command opcode could not be

 

 

 

determined.

Loader response not

7004

D, G

A command response was received from

matched to a known

 

 

the Loader task, but the original command

command

 

 

opcode could not be determined.

Drive response not

7005

D, G

A command response was received from

matched to a known

 

 

a Drive task, but the original command

command

 

 

opcode could not be determined.

Flash response not

7006

D, G

A command response was received from

matched to a known

 

 

the Flash task, but the original command

command

 

 

could not be determined.

Drive index on Update

7007

C, D, G An Updated Drive Status message was

Status message was

 

 

received from a module, but the drive

invalid

 

 

index was out of range.

The Drive response

7008

C, D, G A command response was received from

was not expected

 

 

a Drive task to which a command had not

 

 

 

been sent.

The opcode for a

7009

C, D, G A WORD-sized message was received

WORD message was

 

 

but the message opcode could not be

unknown

 

 

identified.

The opcode for a

700A

C, D, G A DWORD-sized message was received

DWORD message

 

 

but the message opcode could not

was unknown

 

 

identified.

The button causing

700B

C, D, G A command to take the ACL offline was

ACL to go offline was

 

 

completed successfully, but the GUI

unknown

 

 

button that initiated the action could not

 

 

 

be identified.

Destination Xchg was

700C

C, G

Attempting to send a command to a task,

Null

 

 

but the argument exchange pointer was

 

 

 

NULL.

Sending of a cmd

700D

C, G

An attempt to place a command on a task

failed

 

 

exchange failed.

Deactivating a drive

700E

C, G

The Control task is indicating that a

that is not attached

 

 

request to deactivate a drive failed

 

 

 

because the drive is not attached.

 

 

 

 

M8501 and M8502 ACL Tape Drive Installation and User’s Guide 529972-001

6-9

Page 65
Image 65
SMC Networks M8501 manual 2. Fault Symptom Codes, Message