TroubleshootingFault Symptom Codes (FSCs)
Table
Message | FSC | ERP |
|
Control command | 7002 | D, G | A command response opcode from the |
execution failed |
|
| Control task was not anticipated or is un- |
|
|
| identifiable. |
Control response not | 7003 | D,G | A command response was received from |
matched to a known |
|
| the Control task, but the original |
command |
|
| command opcode could not be |
|
|
| determined. |
Loader response not | 7004 | D, G | A command response was received from |
matched to a known |
|
| the Loader task, but the original command |
command |
|
| opcode could not be determined. |
Drive response not | 7005 | D, G | A command response was received from |
matched to a known |
|
| a Drive task, but the original command |
command |
|
| opcode could not be determined. |
Flash response not | 7006 | D, G | A command response was received from |
matched to a known |
|
| the Flash task, but the original command |
command |
|
| could not be determined. |
Drive index on Update | 7007 | C, D, G An Updated Drive Status message was | |
Status message was |
|
| received from a module, but the drive |
invalid |
|
| index was out of range. |
The Drive response | 7008 | C, D, G A command response was received from | |
was not expected |
|
| a Drive task to which a command had not |
|
|
| been sent. |
The opcode for a | 7009 | C, D, G A | |
WORD message was |
|
| but the message opcode could not be |
unknown |
|
| identified. |
The opcode for a | 700A | C, D, G A | |
DWORD message |
|
| but the message opcode could not |
was unknown |
|
| identified. |
The button causing | 700B | C, D, G A command to take the ACL offline was | |
ACL to go offline was |
|
| completed successfully, but the GUI |
unknown |
|
| button that initiated the action could not |
|
|
| be identified. |
Destination Xchg was | 700C | C, G | Attempting to send a command to a task, |
Null |
|
| but the argument exchange pointer was |
|
|
| NULL. |
Sending of a cmd | 700D | C, G | An attempt to place a command on a task |
failed |
|
| exchange failed. |
Deactivating a drive | 700E | C, G | The Control task is indicating that a |
that is not attached |
|
| request to deactivate a drive failed |
|
|
| because the drive is not attached. |
|
|
|
|
M8501 and M8502 ACL Tape Drive Installation and User’s Guide —