TroubleshootingFault Symptom Codes (FSCs)
Table
Message | FSC | ERP |
|
Deactivation of a drive | 700F | C, G | The Control task is indicating that a |
failed |
|
| request to deactivate a drive failed; |
|
|
| reason is not known. |
Drive removal failed | 7010 | C, G | The Drive task is indicating that a request |
|
|
| to |
|
|
| not known. |
Drive is Active failed | 7012 | C, G | The Drive task is indicating that a request |
|
|
| to determine if a drive is executing a host |
|
|
| command failed; reason is not known. |
Control Com | 7013 | C, G | During HotSwap, a command response |
Unidentified |
|
| from the Control task could not be |
|
|
| associated with any outstanding |
|
|
| command. |
Drive status updated | 7014 | C, G | The Drive task is indicating that a request |
failed |
|
| to determine the current state of a drive |
|
|
| failed; reason is not known. |
Loader command | 7015 | C, G | The Loader task is indicating that a |
execution failed |
|
| command has failed to complete |
|
|
| successfully. |
Sequential command | 7016 | C, G | The Sequential task is indicating that a |
execution failed |
|
| command has failed to complete |
|
|
| successfully. |
Destination Xchg for | 7017 | C, G | Attempting to send a message to a task, |
msg. was Null |
|
| but the argument exchange pointer was |
|
|
| Null. |
Bad src mod in peg | 7018 | C, G | A message was received from a remote |
msg |
|
| module, but the module number was out |
|
|
| of range. |
A Peg message has a | 7019 | C, G | Peg message wrapping a Null msg. ptr. |
pointer to Null. |
|
|
|
Xchg conversion | 701A | C, G | Attempt to determine the module number |
failed |
|
| containing the task that is returning a |
|
|
| command response failed. |
Invalid | 701B | C, G | Attempt to send a command to a drive, |
to convert |
|
| but the logical drive number is out of |
|
|
| range. |
Invalid | 701C | C, G | Attempt to send a command to a drive, |
to convert |
|
| but the physical drive number is out of |
|
|
| range. |
Invalid mod number to | 701D | C, G | Attempt to send a command to a drive in |
convert |
|
| a remote module, but the module number |
|
|
| is out of range. |
|
|
|
|
M8501 and M8502 ACL Tape Drive Installation and User’s Guide —