Smeg CS19ID-6 Levelling, Instructions for the Installer, Operation at 380-415V3N~ use a H05RR

Models: CS19ID-6 CS19IDA-6

1 32
Download 32 pages 11.29 Kb
Page 5
Image 5
Operation at 380-415V3N~: use a H05RR-

Instructions for the Installer

Operation at 380-415V3N~: use a H05RR-

F five-wire cable (cable of 5 x 2.5 mm2).

Operation at 380-415V2N~: use a H05RR-

F four-wire cable (cable of 4 x 4 mm2).

Operation at 220-240 V~: use a H05RR-F / H05RNF three-wire cable (cable of 3 x 6 mm2).

The earth wire (yellow-green) must be at least 20 mm longer than the other wires at the end for connection to the appliance.

The power supply cable must be fitted with a suitable five-pin plug (see technical data plate) or, for appliances operating on 220-240V, a three- pin plug. The power supply plug and wall socket must be of the same type (in compliance with CEI standards). The appliance must be earthed appropriately. Before connecting it, check that the power supply line is properly earthed. The use of reductions, adapters or junctions is not recommended.

The manufacturer declines all responsibility for injury or damage caused by failure to comply with the above regulations or deriving from tampering with even just one part of the appliance.

2.2 Levelling

Level the appliance by means of its four adjustable feet. To make the adjustment, undo the lock-nut and unscrew the foot. The adjuster screw travel is 10 mm.

39

Page 5
Image 5
Smeg CS19ID-6, CS19IDA-6 manual Levelling, Instructions for the Installer, Operation at 380-415V3N~ use a H05RR