SonicWALL PortShield Interfaces
164
SonicOS Enhanced 4.0 Administrator Guide
8. After you select a zone option, the management software displays a more expanded
version of the PortShield Interface Settings dialog box.
9. Type a string in the PortShield Interface Name field.
10. Click on the IP Assignment list box and select either Static or Transparent. Static
indicates the interface obtains its IP address manually. Transparent mode allows for the
WAN subnetwork to be shared by the current interface using Address Object assignments.
The interface’s IP address will be the same as the WAN interface IP address.
11. Type an available IP address in the IP Address field.
12. If you want to specify a range of IP addresses different than the one allowed by the
subnetwork mask 255.255.255.0 (Class C network), type in the desired subnetwork mask
value in the Subnet Mask field.
13. Click on a checkbox in the Management area to indicate the desired management protocol
type. The options are:
HTTP
HTTPS
Ping
SNMP
14. Click on a checkbox in the User Login area. This is a special feature that enables you to set
up a Web access environment so you can enforce User Level Authentication.
15. Click on the Create Default DHCP Lease Scope in the DHCP Server field to indicate that
the amount of time allowed for an IP address issued by DHCP will be the default.