Setting the Time Data
This unit is provided with the following functions related to time data.
•Display and reset CNT value
•Set, display, record, and play back SMPTE/EBU time code and user bit data
When the unit is equipped with an optional DSBK- 130/130P Time Code Input/Output Board, it can output the time code read from the tape as an analog (LTC) signal while in
Note
Even when the unit is equipped with the
The following explains how to use these functions.
Displaying Time Data and Operation Mode IndicationsTime data and operation mode indications can be displayed on the monitor screen.
Time data can also be displayed in the time counter display on this unit.
To view time data and operation mode indications on the monitor screenSelect the DISPLAY CONTROL menu item and set “CHARA. DISPLAY” to “ON” (factory default setting).
The time data and the indication of the unit’s current operation mode are superimposed on the composite video signal that is being output from the VIDEO OUT 2 (SUPER) connector, and can be viewed on the monitor screen.
Use the DISPLAY CONTROL menu item to select the information displayed and the character type and position of the indications.
For details of these menu settings, see Chapter 4 “Menu Settings”.
When you set “SUB STATUS” under the DISPLAY CONTROL menu item to other than “OFF”, you can also display supplementary status information on the monitor screen about the editing mode settings, recording format of playback tape, and/or time code generator’s operating mode.
For details of supplementary status information, see “Displaying Supplementary Status Information” (page 55).
Monitor screen contentsThe contents of the monitor screen are shown below.
ATime data type Time data
BDrop frame indication for time code readera)
C Drop frame indication for time code generatora)
T C R 0 0 : 0 4 . 4 7 . 0 7
P L A Y | L O C K |
D
a)This character can appear on the
The following time data type indications are displayed.
Indication | Description |
|
|
CNT | Count value of the time counter |
|
|
TCR | Time code data from time code reader |
| (factory default setting) |
|
|
UBR | User bit data from time code reader |
TCG | Time code data from time code generator |
UBG | User bit data from time code generator |
|
|
T∗R | Time code data from time code reader. The |
| asterisk indicates an interpolation by the time |
| code reader to make up for the time code |
| data not correctly read from the tape. |
U∗R | User bit data from the time code reader. The |
| asterisk indicates that last data is retained by |
| the time code reader, as the new data has not |
| been read correctly from the tape. |
. | Drop frame mode (factory default setting) |
:
OperationOperationtingEd for Functions ientConveEditing3 Chapterfor Functions Convenient 3 Chapter
Chapter 3 Convenient Functions for Editing Operation | 31 |