Menu contents (Continued)

DISPLAY CONTROL [Display]: Settings related to

 

Description of settings

indications on the monitor and the unit

 

 

 

 

 

OVER DISP HOLD [> Hold OVER]: Determine whether or not

OFF [>> OFF]: Do not hold the OVER indication display.

to hold the OVER indication display on the audio level

ON [>> ON]: Hold the OVER indication display.

meter once the indication lights.

 

 

 

 

 

Note

 

 

 

With “ON” selected, once the display is held it will remain held

 

 

unless you change the setting to “OFF”.

BRIGHTNESS [> Brightness]: Set the brightness of front

 

Set brightness as a percentage of the maximum.

panel indicators.

 

100% [>> 100%]

 

66% [>> 66%]

 

33% [>> 33%]

 

 

 

ALARM [> ALARM]: Determine whether alarm messages are

 

ON [>> ON]: Alarm messages are issued.

issued or not.

 

OFF [>> OFF]: Alarm messages are not issued.

 

 

 

REF. ALARM [> REF ALARM]: Determine whether alarm

 

ON [>> ON]: Alarm messages are issued.

messages related to reference video signal are issued or

 

ON (LIMITED) [>> ON (Limit)]: Alarm messages are issued

not.

 

only during recording mode, EE mode, and while editing.

 

 

OFF [>> OFF]: Alarm messages are not issued.

 

 

 

 

TIME CODE [Time code]: Settings related to the time code

 

Description of settings

generator

 

 

 

 

 

 

 

TC MODE [> TC MODE]: Determine whether to use internal

 

INT PRESET [>> INT]: Use internal time code.

time code (generated by the internal time code generator)

 

EXT REGEN [>> EXT]: Use external time code.

or external time code.

 

 

 

 

 

 

Notes

 

 

 

• To be able to input an LTC signal from external equipment, it

 

 

is necessary to install the optional DSBK-130/130P Time

 

 

Code Input/Output Board in this unit.

 

 

• When the selected input mode is “QSDI” (the QSDI indicator

 

 

is lit in the INPUT MODE display), setting “TC MODE” under

 

 

the TIME CODE menu item to “EXT REGEN” causes the

 

 

internal time code generator to automatically synchronize

 

 

with the external time code input to the unit via the QSDI

 

 

interface.

 

 

 

RUN MODE [> RUN mode]: Select the time code generator’s

 

FREE RUN [>> FREE RUN]: Time code generator keeps

advancement (RUN) mode.

 

running.

 

 

REC RUN [>> REC RUN]: Time code generator only runs

 

 

while recording.

 

 

 

 

 

Note

 

 

 

Set to “FREE RUN” when carrying out editing with an editing

 

 

controller. With the “REC RUN” setting, editing and other

 

 

operations will not be carried out correctly.

 

 

 

(Only on DSR-85)

 

ON (DF) [>> ON (DF)]: Drop frame mode

DF MODE [> DF mode]: Select whether the time code

 

OFF (NDF) [>> OFF (NDF)]: Non-drop frame mode

generator and time counter operate in drop frame mode or

 

 

 

 

non-drop frame mode.

 

 

 

 

Normally select drop frame mode, to keep in sync with real

 

 

 

 

time. The non-drop frame mode is useful for example

 

 

 

 

when using computer graphics, and working on a frame

 

 

 

 

count basis.

 

 

 

 

 

 

 

 

 

 

 

 

 

(Continued)

Settings Menu 4 Chapter

Chapter 4 Menu Settings 45