1 Press the SCH button on the vectorscope.
The vectorscope switches to “SCH” mode.
2 Press the B channel button on the vectorscope.
This displays the black burst signal from the switcher.
3 Press the EXT button on the vectorscope.
This switches the vectorscope to external synchronization mode.
4 Adjust the phase synchronization control on the vectorscope so that the sync and subcarrier phases are close to the reference line.
Sync phase | Reference line |
Subcarrier phase |
Align the sync and subcarrier phase of the black burst signal to the reference line.
5 Output the player 1 signal from the
This displays the sync phase and subcarrier phase (composite signals only) of the signal from player 1.
7 On player 1, adjust the SYNC and SC controls, using a Phillips screwdriver, so that the output from player 1 on channel (A) is in correct phase alignment with the black burst signal on channel
(B).
This indicator |
|
|
| This indicator |
|
| |||
moves as you |
| |||
| moves as you | |||
turn the SYNC |
| |||
| turn the SC | |||
control. |
| |||
| control. | |||
|
|
|
|
Adjust the sync and subcarrier phase of the output signal from player 1.
Note
When component signals are used the subcarrier phase indicator does not appear.
8 Output the player 2 signal from the
Settings and Connections 5 Chapter
Chapter 5 Connections and Settings | 67 |