OPERATIONAL FUNCTION [Operational]: Operation settings

Description of settings

 

 

 

LOCAL ENABLE [> Local ENA]: Select which of the recording/

 

ALL DISABLE [>> All DIS]: All of the recrding/playback

playback control buttons (PREV, PLAY, NEXT, STOP, and REC)

 

control buttons are disabled.

operate when the control mode selector is set to “REMOTE.”

 

*STOP [>> STOP]: Only the STOP button is enabled.

 

 

 

ALL ENABLE [>> All ENA]: All of the recording/playback

 

 

 

control buttons are enabled, and settings such as

 

 

 

preroll time change or time data display selection are

 

 

 

effective.

 

 

 

REC MODE [>REC mode]: Select the recording mode.

 

*NORMAL REC [>>Normal]: Normal recording.

 

 

 

PRE ALARM REC [>>Pre Alarm]: Pre-alarm recording.

 

 

 

CONT. REC [>>Cont. REC]: Continuous recording.

 

 

 

INTERVAL REC [>>Interval]: Interval recording (settings

 

 

 

required in next item, INTERVAL REC).

 

 

 

 

INTERVAL REC [>Interval

INTERVAL [>>Int Time]: Set

 

*30 sec [>>>30 SEC]: 30 seconds

REC]:

the standby interval for

 

1 min [>>>1 MIN]: 1 minute.

Set the standby and

interval recording.

 

5 min [>>>5 MIN]: 5 minutes.

recording intervals for

 

 

10 min [>>>10 MIN]: 10 minutes.

interval recording.

 

 

 

 

REC TIME [>>Rec Time]: Set

 

*0.5 sec [>>>0.5SEC]: 0.5 seconds.

 

 

 

the recording interval for

 

1.0 sec [>>>1.0SEC]: 1.0 second.

 

interval recording.

 

1.5 sec [>>>1.5SEC]: 1.5 seconds.

 

 

 

2.0 sec [>>>2.0SEC]: 2.0 seconds.

 

 

 

 

REC INHIBIT [> REC INH]: Determine whether to prohibit

 

*OFF [>> OFF]: Do not prohibit recording.

recording.

 

 

ON [>> ON]: Prohibit recording. (The REC INHI indicator

 

 

 

in the display section lights.)

 

 

 

SEARCH ENABLE [> Search ENA]: Select how the unit enters the

 

*DIAL DIRECT [>> DIAL]: Press the SEARCH button or,

search mode.

 

 

except during recording, turn the search dial.

 

 

 

VIA SEARCH KEY [>> via KEY]: Press the SEARCH

 

 

 

button.

 

 

 

 

MAX SRCH SPEED [> Max

SHUTTLE [>> SHUTTLE]:

 

X60 [>>> X60]: Maximum 60 times normal speed

SRCH]:

Specify the maximum

 

*X32 [>>> X32]: Maximum 32 times normal speed

Specify the maximum

search speed in shuttle

 

X16 [>>> X16]: Maximum 16 times normal speed

search speed in search

mode.

 

 

 

(shuttle) mode and F. FWD

 

 

 

 

F. FWD/REW [>> F. FWD/

 

MAX [>>> MAX]: No maximum search speed is specified.

(fast forward)/REW (rewind)

 

REW]:

 

*X85 [>>> X85]: Maximum 85 times normal speed

mode.

 

Specify the maximum

 

X60 [>>> X60]: Maximum 60 times normal speed

 

 

 

search speed in F. FWD/

 

X32 [>>> X32]: Maximum 32 times normal speed

 

REW mode. a)

 

 

 

 

Note

 

 

 

 

When

this item is set to MAX, the playback video signal is

 

 

 

muted.

 

 

 

 

 

JOG RESPONSE [>JOG dial]:

 

TYPE1 [>>type 1]: Search speed varies linearly over the

 

Set the search speed

 

range -1 to +1 times normal speed.

 

corresponding to number of

 

TYPE2 [>>type 2]: Search speed varies in stepwise

 

search dial rotations in jog

 

manner over the range –3 to +3, as shown in

 

mode.

 

“TYPE2” b) in figure below. (In the ±1 speed section,

 

 

 

speed does not vary, regardless of search dial

 

 

 

rotations.)

 

 

 

TYPE3 [>>type 3]: Search speed varies linearly over the

 

 

 

range –3 to +3, as shown in “TYPE3” c) in figure

 

 

 

below.

 

 

 

 

PREROLL TIME [> Preroll]:

 

 

15 SEC [>> 15 sec] to 0 SEC [>> 0 sec]: The preroll time

Set the preroll time.

 

 

can be set in one-second increments to between 0

 

 

 

and 15 seconds.

 

 

 

A preroll time of at least 5 seconds is recommended when

 

 

 

using this unit for editing. When an editing control unit

 

 

 

such as the PVE-500 has been connected, this setting is

 

 

 

disabled and the setting on the editing control unit is in

 

 

 

effect. Operations such as the preroll time setting and the

 

 

 

time data switching operation are also performed on the

 

 

 

editing control unit.

 

 

 

Factory default setting: 5 SEC [>> 5 sec]

 

 

 

AFTER CUE-UP [> After CUE]: Select the operating mode

 

*STOP [>> STOP]: Stop mode

following cue-up.

 

 

STILL [>> STILL]: Output still pictures in search mode.

 

 

 

 

 