Overview 1 Chapter
either as channels 1 and 2 or as channels 3 and 4. The two audio channels can be output also either as channels 1 and 2 or as channels 3 and 4.
Compact SizeThe compact size of the unit makes the unit suitable for use on a desk top or in an outside broadcast van. The unit can be used as feeder machine for
This unit is the first DVCAM format player or recorder to provide noiseless, variable speed playback over the range from
When searching at speeds in the range ±2 times normal speed, the digital jog sound function is enabled. The audio signal is saved in temporary memory, and replayed according to the search speed. This allows searching on the sound track.
Video process controlFor analog video output and
This unit is equipped with a responsive search dial for jog and shuttle playback.
Internal and external time codesAn internal time code generator and reader enables time code compliant with SMPTE (for
Outputting or inputting time code (LTC) to or from an external device is also possible using the TIME CODE IN/ OUT connectors.
The unit is also compatible with VITC.
Remote controlThis unit has two
Under the control of external control devices, this unit can play back editing segments over the range
Time code values, operation mode indications, error messages, and other text data can be superimposed on analog composite video signals output from the SUPER connector. The SUPER connector is a special connector for output of text information. It can be used independently when you are outputting composite video, component video,
The unit is equipped with a mass storage hard disk, which allows a maximum of 12 hours of 25 Mbps DVCAM stream signals to be recorded.
Rich variety of recording modes•Normal recording: Input signals are recorded to the hard disk. A single clip* is created by recording start and stop operations.
•Continuous (endless) recording: This mode allows continuous recording of new material to the hard disk, overwriting old material when the disk becomes full. This mode is suitable for meteorological and biological observations, which require long continuous recording times.
•Interval recording: This mode allows recording at specified intervals. You can set the length of the recording interval and the length of the standby time until the next recording interval. The recording interval can be set to 0.5, 1, 1.5, or 2 seconds, and the standby interval to 30 seconds or 1, 5, or 10 minutes. This is effective in situations such as biological observations when long interval recording times are required.
•
*Material recorded by this unit is handled in units called “clips”, which contain the data from the start point to the end point of one recording operation. Note that there is a limit of 500 on the number of clips that can be saved, regardless of the available hard disk space.
8 Features