HCD-C5

Adjustment flow

Start

YES

Replace IC195

NO

• Abbreviation

OP: optical pick-up

After turning off and then on the power, initialize the EEPROM

For details, refer to “WHEN MEMORY NG IS DIS- PLAYED” in Section 4. TEST MODE (See page 29)

YES

Replace OP or IC195

7.INITIAL SETTING OF ADJUSTMENT VALUE (See page 40)

NO

YES

Replace IC101, IC195, or D101

9.TEMPERATURE COMPENSATION OFFSET ADJUSTMENT (See page 40)

NO

YES

Replace OP, IC190, or IC195

10. LASER POWER ADJUSTMENT (See page 40)

NO

Replace OP, IC102, IC190,

YES

11. Iop NV SAVE (See page 41)

or IC195

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

12. TRAVERSE ADJUSTMENT (See page 41)

Replace OP, IC101, IC151,

13. FOCUS BIAS ADJUSTMENT (See page 43)

or IC195

 

 

16. AUTO GAIN CONTROL OUTPUT LEVEL

 

 

 

 

 

ADJUSTMENT (See page 44)

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

Replace OP

8. RECORDING AND DISPLAYING THE IOP

 

 

INFORMATION (See page 40)

 

 

 

 

 

 

 

 

 

 

 

 

NO

6-4. Auto Check (See page 38)

End adjustments

35

Page 35
Image 35
Sony HCD-C5 service manual Adjustment flow, Yes