HCD-C5

2.PRECAUTIONS FOR CHECKING LASER DIODE EMISSION

To check the emission of the laser diode during adjustments, never view directly from the top as this may lose your eye-sight.

3.PRECAUTIONS FOR USE OF OPTICAL PICK-UP (KMS-260B/260E)

As the laser diode in the optical pick-up is easily damaged by static electricity, solder the laser tap of the flexible board when handling it.

Before disconnecting the connector, solder first. Before connecting the connector, be careful not to remove the solder. Also take adequate measures to prevent damage by static electricity. Handle the flexible board with care as it breaks easily.

pick-up

flexible board

 

laser tap

Optical pick-up flexible board

4. PRECAUTIONS FOR ADJUSTMENTS

1.When replacing the following parts, perform the adjustments and checks with in the order shown in the following table.

2.Set the MD test mode when performing adjustments. After completing the adjustments, exit the MD test mode. Perform the adjustments and checks in “Group Service” of the MD test mode.

3.Perform the adjustments to be needed in the order shown.

4.Use the following tools and measuring devices.

Check Disc (TDYS-1) (Part No. : 4-963-646-01)

Test Disk (MDW-74/GA-1) (Part No. : 4-229-747-01)

Laser power meter LPM-8001 (Part No. : J-2501-046-A)

or MD Laser power meter 8010S (Part No. : J-2501-145-A)*1

Oscilloscope (Measure after performing CAL of prove.)

Digital voltmeter

Thermometer

Jig for checking BD (MD) board waveform (Part No. : J-2501-196-A)

5.When observing several signals on the oscilloscope, etc., make sure that VC and ground do not connect inside the oscilloscope.

(VC and ground will become short-circuited.)

6.Using the above jig enables the waveform to be checked without the need to solder.

(Refer to Servicing Notes on page 6.)

7.As the disc used will affect the adjustment results, make sure that no dusts nor fingerprints are attached to it.

*1 Laser power meter

When performing laser power checks and adjustment (electrical adjustment), use of the new MD laser power meter 8010S (Part No. J-2501-145-A) instead of the conventional laser power meter is convenient.

It sharply reduces the time and trouble to set the laser power meter sensor onto the objective lens of optical pick-up.

 

 

 

 

Parts to be replaced

 

 

 

Adjustment

 

 

 

 

 

 

 

Optical

IC101

IC102

IC151

IC190

IC195

D101

 

Pick-up

 

 

 

 

 

 

 

7. Initial setting of adjustment value

8.Recording of Iop information

9.Temperature compensation offset adjustment

10.Laser power adjustment

11.Iop NV Save

12.Traverse adjustment

13.Focus bias adjustment

16.Auto gain control output level adjustment

6-4. AUTO CHECK

36

Page 36
Image 36
Sony HCD-C5 Precautions for Checking Laser Diode Emission, Precautions for USE of Optical PICK-UP KMS-260B/260E