iCAMERA connector (optical fiber connector) Used to connect a video camera, using an optical fiber cable. All video camera signals, including power supply, control, video, and audio, are sent and received over one optical fiber cable.

Note

Dust on the connection surface of the optical fiber cable may result in transmission errors. When not connected, always cover the end of the connector with the supplied cap.

jExpansion slots

For installation of an optional HKCU1001 SD Encoder Unit, HKCU1003 Multi Interface Unit, or HKCU1005 SDI Output Expansion Unit.

For details on installation, contact a Sony service or sales representative.kINTERCOM/TALLY/PGM (intercom/tally/program audio) connector (D-sub 25-pin)

Used for input and output of intercom, tally, and program audio signals. Connect to the intercom/tally/program audio connector of the intercom system.

lMIC REMOTE (microphone remote) connector (D-sub 15-pin)

Using this connector, the video camera’s microphone input level may be set by external equipment such as an audio mixer, in five level (-60, -50, -40, -30, and -20 dB). When shooting, set the volume to a level appropriate for the audio conditions.

This connector also supplies a red tally signal and a green tally signal.

The microphone input level may also be set using the setup menu. For details on the setup menu, contact a Sony service or sales representative.

mWF REMOTE (waveform monitor remote) connector (D-sub 15-pin)

Used to attach to the appropriate connector on a recall-type waveform monitor when operating the waveform monitor display using an MSU-900 series Master Setup Unit or an RCP-700/900 series Remote Control Panel.When using a recall-type monitor, preset a display mode on the waveform monitor, and then recall the mode externally.

For details on these operations, refer to the Master Setup Unit or Remote Control Panel manuals.

nTRUNK LINE connector (D-sub 9-pin)

Used to connect to the CCU connector on a video camera via an RS-232C interface. Used mainly for communication with equipment on the camera side.

Communication with up to two channels is available.
oI/O PORT connector (D-sub 15-pin)Used for remote control using an external control device.

Note

Use of a case wider than 42 mm can cause interference at connectors 2, 4, 5. It is recommended that you use a JAE- made DA-C1-J10.

pWF MODE (waveform monitor mode output)connectors (4-pin)

Connect to the appropriate connector on a waveform monitor when monitoring a signal in sequential mode.

A sequence signal will be output when the SEQ button on the RCP-700/900 series Remote Control Panel is pressed, allowing simultaneous monitoring of the R, G, and B signals in sequential mode. When both the RCP and MSU are in use, this connector functions as the output connector for RCP control.

For details on these operations, refer to the Master Setup Unit or Remote Control Panel manuals.

qRCP/CNU connector (8-pin)

Used to connect to an MSU-900 series Master Setup Unit, CNU-700 Camera Command Network Unit, or RCP-700/ 900 series Remote Control Panel via a CCA-5 Connection Cable. Control signals are sent and received via this connector.

When using an RCP-700/900 series unit, power is also supplied.rTRUNK A connector (12-pin)

Used to connect to the CCU connector on a video camera via an RS-232C or RS-422A interface. Communication with up to two channels is available.

sMIC1, MIC2 (microphone output 1, 2) connectors (XLR 3-pin)Used to supply the microphone signal sent from the video camera.tAC IN (AC power input) connector

Use the specified AC power cord to connect to an AC power supply. The AC power cord can be secured to this unit, using the plug holder (optional).

HKCU1001 SD Encoder Unit (optional)

Note

To reduce the risk of electric shock, fire or injury, do not open the cabinet. To adjust the internal settings, refer to qualified service personnel.

Locations and Functions of Parts

39