Error code

Description

Display

Logged

 

 

 

 

 

Detected SCSI parity error.

 

 

22

Command phase retried but

Yes

 

gave up.

 

 

 

 

 

 

 

Detected SCSI parity error.

 

 

23

Data Out phase retried but

Yes

 

gave up.

 

 

 

 

 

 

 

Detected a parity error

 

 

24

message. Message In phase

Yes

 

retried but gave up.

 

 

 

 

 

 

 

Received Initiator detected

 

 

25

error message. Message

Yes

 

phase retried but gave up.

 

 

 

 

 

 

 

Received Initiator detected

 

 

26

error message. Command

Yes

 

phase retried but gave up.

 

 

 

 

 

 

 

Received Initiator detected

 

 

27

error message. Status phase

Yes

 

retried but gave up.

 

 

 

 

 

 

 

Received Initiator detected

 

 

28

error message. Data In phase

Yes

 

retried but gave up.

 

 

 

 

 

 

 

Received Initiator detected

 

 

29

error message. Data Out

Yes

 

phase retried but gave up.

 

 

 

 

 

 

2A

Received an illegal message

Yes

from the SCSI interface.

 

 

 

 

 

 

 

2B

Received an illegal Identify

Yes

message at the SCSI interface

 

 

 

 

 

 

 

2C

Failed reselection. Reselection

Yes

retried but gave up.

 

 

 

 

 

 

 

 

REQ/ACK handshake timeout

 

 

2F

or controller chip interruption

Yes

 

timeout at the SCSI interface.

 

 

 

 

 

 

30

Reports a unit attention event.

Yes

 

 

 

 

 

An as yet unsupported LUN

 

 

31

specified at the SCSI

Yes

 

interface.

 

 

 

 

 

 

32

Loader not yet ready.

Yes

 

 

 

 

33

Loader front door open.

Yes

 

 

 

 

34

Currently in reprogramming

Yes

mode.

 

 

 

 

 

 

 

35

Currently in menu mode.

Yes

 

 

 

 

36

Reported an information

Yes

exception condition.

 

 

 

 

 

 

 

 

Reception of drive data

[L ] and [4 1] appear

 

41

timeout at the drive interface.

alternately on the message

Yes

 

 

display.

 

 

 

 

 

 

Received data of abnormal

[L ] and [4 2] appear

 

42

length from drive at the drive

alternately on the message

Yes

 

interface.

display.

 

 

 

 

 

 

Drive detected as offline at the

[L ] and [4 3] appear

 

43

drive interface.

alternately on the message

Yes

 

 

display.

 

 

 

 

 

 

Detected calibration error

[L ] and [7 0] appear

 

70

(lower sensor readings

alternately on the message

Yes

 

abnormal).

display.

 

 

 

 

 

Appendix 48