Error code

Description

Display

Logged

 

 

 

 

 

Detected SCSI parity error.

 

 

22

Command phase retried but

—

Yes

 

gave up.

 

 

 

 

 

 

 

Detected SCSI parity error.

 

 

23

Data Out phase retried but

—

Yes

 

gave up.

 

 

 

 

 

 

 

Detected a parity error

 

 

24

message. Message In phase

—

Yes

 

retried but gave up.

 

 

 

 

 

 

 

Received Initiator detected

 

 

25

error message. Message

—

Yes

 

phase retried but gave up.

 

 

 

 

 

 

 

Received Initiator detected

 

 

26

error message. Command

—

Yes

 

phase retried but gave up.

 

 

 

 

 

 

 

Received Initiator detected

 

 

27

error message. Status phase

—

Yes

 

retried but gave up.

 

 

 

 

 

 

 

Received Initiator detected

 

 

28

error message. Data In phase

—

Yes

 

retried but gave up.

 

 

 

 

 

 

 

Received Initiator detected

 

 

29

error message. Data Out

—

Yes

 

phase retried but gave up.

 

 

 

 

 

 

2A

Received an illegal message

—

Yes

from the SCSI interface.

 

 

 

 

 

 

 

2B

Received an illegal Identify

—

Yes

message at the SCSI interface

 

 

 

 

 

 

 

2C

Failed reselection. Reselection

—

Yes

retried but gave up.

 

 

 

 

 

 

 

 

REQ/ACK handshake timeout

 

 

2F

or controller chip interruption

—

Yes

 

timeout at the SCSI interface.

 

 

 

 

 

 

30

Reports a unit attention event.

—

Yes

 

 

 

 

 

An as yet unsupported LUN

 

 

31

specified at the SCSI

—

Yes

 

interface.

 

 

 

 

 

 

32

Loader not yet ready.

—

Yes

 

 

 

 

33

Loader front door open.

—

Yes

 

 

 

 

34

Currently in reprogramming

—

Yes

mode.

 

 

 

 

 

 

 

35

Currently in menu mode.

—

Yes

 

 

 

 

36

Reported an information

—

Yes

exception condition.

 

 

 

 

 

 

 

 

Reception of drive data

[L ] and [4 1] appear

 

41

timeout at the drive interface.

alternately on the message

Yes

 

 

display.

 

 

 

 

 

 

Received data of abnormal

[L ] and [4 2] appear

 

42

length from drive at the drive

alternately on the message

Yes

 

interface.

display.

 

 

 

 

 

 

Drive detected as offline at the

[L ] and [4 3] appear

 

43

drive interface.

alternately on the message

Yes

 

 

display.

 

 

 

 

 

 

Detected calibration error

[L ] and [7 0] appear

 

70

(lower sensor readings

alternately on the message

Yes

 

abnormal).

display.

 

 

 

 

 

Appendix 48