When problems occur, the ERROR/WARNING or CLEANING LED lights or flashes, and one of the following codes appears on the message display.
ERROR
WARNING
CLEANING
LED | Lit/Flashing | Code | Description | Remedy | |
|
|
|
|
|
|
|
|
| [L ] and [X X] |
|
|
|
|
| appear alternately | Loader error. | Restart the system and verify if the |
|
|
| on the message |
| error message disappears. If it occurs |
|
|
| display. |
| again, note the error code and contact |
|
|
| [d ] and [X X] |
| customer service for repair. For details |
ERROR/ |
|
| appear alternately | AIT drive error. | on error codes, see “Error Code List” |
WARNING | Flashing (orange) | on the message | |||
|
|
| display. |
|
|
|
|
|
|
|
|
|
|
| [C ] and [X X] |
| Replace the data cartridge after |
|
|
| appear alternately | Data cartridge error. | cleaning the AIT drive. If the same |
|
|
| on the message | problem occurs after doing so, contact | |
|
|
|
| ||
|
|
| display. |
| customer service for repair. |
|
|
|
|
|
|
|
|
| 0 1 | Cartridge not completely | Open the front door and reinsert |
|
|
| inserted. | cartridges as necessary. | |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| Cleaning cartridge not | Insert the cleaning cartridge in |
|
|
| 0 3 | inserted at the beginning of | |
|
|
|
| cleaning. | slot CL/8. |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| A data cartridge was | Insert the cleaning cartridge in |
|
|
| 0 4 | inserted in slot CL/8 at the | |
|
|
| slot CL/8. | ||
|
|
|
| beginning of cleaning. | |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| The DOOR button is |
|
|
|
| 0 5 | pressed, when the front | Do not attempt to open the front door |
|
|
| door is locked by an | manually. | |
|
|
|
| ||
|
|
|
| application. |
|
ERROR/ |
|
|
|
|
|
|
|
|
| Make sure that the operating | |
WARNING | Lit (orange) |
| Internal temperature | environment is within the allowed | |
|
|
| 0 6 | temperature limits (5 to 40°C) and | |
|
|
| abnormally high. | ||
|
|
|
| verify that AIT autoloader fan is | |
|
|
|
|
| |
|
|
|
|
| operating normally. |
|
|
|
|
|
|
|
|
| 0 7 | Parts replacement needed. | For replacement parts, contact |
|
|
|
|
| customer service. |
|
|
|
| Too many cartridges in the |
|
|
|
| 0 8 | loader. (There are | Eject one or more cartridges from the |
|
|
| cartridges in all the slots | AIT autoloader. | |
|
|
|
| ||
|
|
|
| and the AIT drive.) |
|
|
|
|
|
|
|
|
|
|
| The internal temperature of | Make sure that the operating |
|
|
| 0 9 | the device is too low to | environment is within the allowed |
|
|
|
| guarantee operation. | temperature limits (5 to 40°C). |
|
|
|
|
|
|
|
|
|
|
| Clean the AIT drive. If the CLEANING |
|
|
|
|
| LED starts flashing again, repeat |
|
|
|
|
| cleaning up to three times. Also verify if |
CLEANING |
|
| C L | AIT drive cleaning request. | the cleaning cartridge has reached the |
Flashing (green) | end of its service life. If after performing | ||||
|
|
| the above the CLEANING LED | ||
|
|
|
|
| |
|
|
|
|
| continues flashing, contact customer |
|
|
|
|
| service for repair. |
|
|
|
|
|
|
Appendix 53