5-2. PRECAUTIONS FOR CHECKING LASER DIODE EMISSION
To check the emission of the laser diode during adjustments, never view directly from the top as this may lose your
5-3. PRECAUTIONS FOR USE OF OPTICAL PICK- UP (KMS-260B)
As the laser diode in the optical
flexible board | |
|
laser tap
Optical
5-4. PRECAUTIONS FOR ADJUSTMENTS
1)When replacing the following parts, perform the adjustments and checks with in the order shown in the following table.
2)Set the test mode when performing adjustments. After completing the adjustments, exit the test mode.
Perform the adjustments and checks in “group S” of the test mode.
3)Perform the adjustments to be needed in the order shown.
4)Use the following tools and measuring devices.
•Check Disc (MD)
•Test Disk
•Laser power meter
or
MD Laser power meter 8010S (Parts No.
•Oscilloscope (Measure after performing CAL of prove.)
•Digital voltmeter
•Thermometer
•Jig for checking BD board waveform (Parts No. :
5)When observing several signals on the oscilloscope, etc., make sure that VC and ground do not connect inside the oscillo- scope.
(VC and ground will become
6)Using the above jig enables the waveform to be checked without the need to solder.
(Refer to Servicing Note on page 6.)
7)As the disc used will affect the adjustment results, make sure that no dusts nor fingerprints are attached to it.
|
|
| Parts to be replaced |
|
| ||
Adjustment |
|
|
|
|
|
|
|
optical | IC101 | IC102 | IC151 | IC190 | IC195 | D101 | |
| |||||||
|
|
|
|
|
|
|