10.Rotate the AMS knob until the waveform of the oscilloscope moves closer to the specified value.

In this adjustment, waveform varies at intervals of approx. 2%. Adjust the waveform so that the specified value is satisfied as much as possible.

(Traverse Waveform)

A

VC

B

Specification A = B

11.Press the @/1 button, and save the adjustment results in the non-volatile memory. (“EFB = SAVE” will be displayed for a moment.)

Next “EF MO ADJUS (C07)” is displayed. The disc stops ro- tating automatically.

12.Press the x/Z “PGM” button and remove the disc.

13.Load the check disc (MD) TDYS-1.

14.Roteto AMS knob and display “EF CD ADJUS” (C08).

15. Press the @/1 button and display “EFB = CD”. Servo is imposed automatically.

16.Rotate the AMS knob so that the waveform of the oscilloscope moves closer to the specified value.

In this adjustment, waveform varies at intervals of approx. 2%. Adjust the waveform so that the specified value is satisfied as much as possible.

(Traverse Waveform)

A

VC

B

Specification A = B

17. Press the @/1 button, display “EFB = SAVE” for a mo- ment and save the adjustment results in the non-volatile memory. Next “EF CD ADJUST” (C08) will be displayed.

18.Press the x/Z “PGM” button and remove the check disc (MD) TDYS-1.

Note 1 : MO reading data will be erased during if a recorded disc is used in this adjustment.

Note 2 : If the traverse waveform is not clear, connect the oscillo- scope as shown in the following figure so that it can be

seen more clearly.

Oscilloscope

BD board

330 k

CN105 pin 4 (TE)

10pF

CN105 pin 6

(VC)

 

5-13. FOCUS BIAS ADJUSTMENT

Adjusting Procedure :

1.Load a test disk (MDW-74/GA-1).

2.Rotate the AMS knob and display “CPLAY1MODE” (C34).

3.Press the @/1 button and display “CPLAY1 MID”.

4. Press the

x/Z

button when “C =

AD = )” is dis-

played.

 

5.Rotate the AMS knob and display “FBIAS ADJUST” (C09).

6.Press the @/1 button and display “ / a = T)”.

The first four digits indicate the C error rate, the two digits after

[/]indicate ADER, and the 2 digits after [a =] indicate the focus bias value.

7.Rotate the AMS knob in the clockwise direction and find the focus bias value at which the C error rate becomes 200 (Refer to Note 2).

8.Press the @/1 button and display “ / b = T”.

9.Rotate the AMS knob in the counterclockwise direction and find the focus bias value at which the C error rate becomes 200.

10.Press the @/1 button and display “ / c = T)”.

11.Check that the C error rate is below 20 and ADER is 00. Then

 

press the

@/1

button.

 

 

 

 

12.

If the “(

” in “ - -

 

( ” is above 20, press the

@/1

 

button.

 

 

 

 

 

 

 

 

If below 20, press the

 

x/Z

button and repeat the

 

adjustment from step 2.

 

 

 

 

13.

Press the

x/Z “PGM”

 

button to remove the test disc.

Note 1 : The relation between the C error and focus bias is as shown in the following figure. Find points a and b in the following figure using the above adjustment. The focal point position c is automatically calculated from points a and b.

Note 2 : As the C error rate changes, perform the adjustment using the average vale.

Cerror

200

b

c

a

Focus bias value

 

 

 

(F. BIAS)