Preparations 2 Chapter
Display |
| Operation mode |
Block A | Block B |
|
VAR | (Speed) | Variable speed |
|
| mode |
|
|
|
TOP 0001/xxxx |
| Cuing up to the first |
|
| frame of the first |
|
| clip. |
|
|
|
END xxxx/xxxx |
| Cuing up to the last |
|
| frame of the last |
|
| clip. |
|
|
|
PREROLL |
| Cuing up during |
|
| preroll |
|
|
|
Displaying Supplementary Status Information
When you set the setup menu item DISPLAY CONTROL >SUB STATUS to other than “OFF” (see page 82), you can view supplementary status information on the monitor screen below the operating mode display area.
| T | C | R |
| 0 | 0 | : | 0 | 4 | . | 4 | 7 | . | 0 | 7 |
|
|
|
|
| P | L | A | Y |
|
|
|
| L | O | C | K |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| I | N | S |
| V |
| A | 1 | 2 | 3 | 4 |
| T | C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Supplementary status information
The following items of supplementary status information are displayed depending on the setting of the menu item
SUB STATUS.
Setting of menu item | Items of supplementary |
SUB STATUS | information displayed |
TC MODE | Operating mode of the internal |
| timecode generator |
|
|
REMAIN | Amount of free capacity on the |
| disc (in minute units). |
|
|
CLIP NO | Clip number |
|
|
The following tables show the
When the menu item SUB STATUS is set to “TC MODE”:
Meaning | |
indication |
|
INT PRST FREE | The internal timecode generator is |
| operating in FREE RUN mode. |
|
|
INT PRST REC | The internal timecode generator is |
| operating in REC RUN mode. |
|
|
INT | The internal timecode generator is in |
| synchronization with the playback |
| timecode (LTC) read from disc. |
|
|
Meaning | |
indication |
|
EXT | The internal timecode generator is in |
| synchronization with the external |
| timecode input to the unit via the |
| S400 connector and is generating the |
| same timecode values and user bit |
| values as those of the external |
| timecode (regeneration). |
|
|
EXT | The internal timecode generator is in |
| synchronization with the external VITC |
| input to the unit via the S400 |
| connector interface and is generating |
| the same timecode values and user bit |
| values as those of the external |
| timecode (regeneration). |
|
|
When the menu item SUB STATUS is set to “REMAIN”:
Meaning | |
indication |
|
REMAIN 120 min | Remaining capacity of the disc in |
| minutes. When the remaining capacity |
| has not been calculated, “REMAIN |
| min” appears. |
|
|
34 Superimposed Text Information