4 Depending on the frame frequency setting of this unit, supply the reference timecode and reference video signal shown in the following table to the TC IN connector 1) and GENLOCK IN connector, respectively. The input reference timecode and reference video signal must meet the phase relationship requirements of the the SMPTE timecode standard. (Excluding the case where the frame frequency is 23.98P.)
1) Input to the TC IN connector.
Set the F-RUN/SET/R-RUN switch to F-RUN.
Set the PRESET/REGEN/CLOCK switch to PRESET.
1
2
3 Press the DISPLAY/EXPAND button of the LCD monitor to display TCG on the time counter display section.
4
3

Example 1: Synchronizing with an external timecode

To synchronize the timecode

 

 

TC IN

External timecode

 

 

GENLOCK IN

Reference video signal (SD or HD)

Example 2: Connecting two units, and using one as the reference

Notes

When making the following connections, set the frame frequency to the same value on both units. Wait until the reference camcorder becomes stable (a state where a normal picture appears on the viewfinder screen or the LCD monitor), and then connect the other camcorders.

When the frame frequency of this unit is 23.98P, make sure that the reference unit is either recording or in the recording stopped state.

MONITOR OUT

TC OUT

Reference camcorder

TC IN

GENLOCK IN

SUB CLIP

 

CLIP MENU

2

 

SEL/SET

PRESET

F-RUN

 

REGEN

SET

 

CLOCK

R-RUN

 

1

Playback and Recording 3 Chapter

Frame

Acceptable reference

Acceptable

frequency of

video signal frame

timecode

this unit

frequency (HD or SD)

 

60i a), 30P b)

59.94i

30 frames

50i, 25P

50i

25 frames

 

 

 

23.98P

59.94i, 23.98PsF

24 frames

 

 

 

a)More precisely 59.94i

b)More precisely 29.97P

Recording – Basic Operations