STATUS menuThis menu is used for displaying the internal condition of the monitor.

 

 

 

 

 

 

S T A T U S

 

 

[ P F M - 5 0 0 A 2 W U ]

 

 

 

 

 

 

 

 

S E R I A L N o .

: 2 0 0 0 0 0 1

 

 

 

 

 

 

 

O P E R A T I O N

: 0 0 0 0 0 0 H

 

 

 

S O F T W A R E

: Ver 1

. 0 0

 

 

 

T E M P E R A T U R E :

O K

 

 

 

 

F A N

:

O K

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model nameIndicates the model name.SERIAL No.Indicates the serial number.OPERATIONIndicates the total operation hours.

Note

The standby mode is not counted as OPERATION time.SOFTWAREIndicates the system software version.TEMPERATUREIndicates whether the internal temperature of the monitor is usual.OK: UsualNG: Unusual

When the internal temperature is unusual, NG is displayed and the item flashes in red. The uindicator on the control panel also flashes.

Note

The “TEMPERATURE NG” message may appear when the ventilation holes are blocked or the monitor is installed in a poorly ventilated area. In this case, check that the ventilation holes are not blocked and install the monitor in a good ventilated area. If the message still displayed, contact your authorized Sony dealer.

When the uindicator flashes or NG indicates, see “Self- diagnosis Function” on page 31(EN).

FAN

The cooling fans are built in this monitor. This item indicates whether the cooling fans work properly.

OK: Usual

NG: Unusual

When the cooling fans are unusual, NG is displayed and the item flashes in red. The uindicator on the control panel also flashes.

Note

When the “FAN NG” message appears, contact your authorized Sony dealer.

When the uindicator flashes or NG indicates, see “Self- diagnosis Function” on page 31(EN).

Cooling fans

Ventilation holes

Note

The upper cooling fans detect the monitor’s internal temperature and control the fans rotations. If the ambient temperature is high, the number of fan rotations increase and the noise will be louder.

21 (EN)