Unit Not Heating Up, “ON” Light Not Lit

SEZ SERIES COUNTERTOP STEAMERS

TROUBLESHOOTING

Unit Not Heating Up, “ON” Light Not Lit

Unit not heating up, “ON” light not lit.

Check that circuit breaker is ON and that proper voltage

is available at main fuse block.

DISCONNECT POWER AT CIRCUIT BREAKER.

Remove control panel without disconnecting plug.

Reconnect power.

Turn lever to “ON” position. Actuate door switch.

Check voltage between A and B on control panel fuse

block (see Figure 7 on page 24).

 

 

Does voltage

 

 

No

 

 

Yes

 

match serial plate

 

 

 

 

 

voltage?

 

 

 

 

 

 

DISCONNECT POWER AT CIRCUIT BREAKER.

Check resistance between contactor terminals

(see Figure 8 on page 25).

 

 

Is

 

 

 

 

measured resistance

 

 

No

 

consistent with the table

 

Yes

 

 

 

 

in Figure 8 on

 

 

 

 

 

 

Check voltage on side C and D on control panel

fuse block (see Figure 7 on page 24).

 

 

 

 

Does voltage

 

 

 

 

 

Yes

 

 

 

 

No

 

 

 

 

match serial plate

 

 

 

 

 

 

 

 

 

 

 

 

voltage?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

page 25)?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace elements

 

Check main fuses and

 

 

and main fuses

 

replace as needed

 

 

(see Figure 9 on page

 

(see Figure 9 on page

 

 

26).

 

26).

 

 

 

 

 

 

 

 

Check voltage across terminals 1 and 6 of terminal block (see Figure 7 on page 24).

Does voltage

No match serial plate voltage?

Check for short circuit in

power switch (see

Figure 10 on page 27),

contactor and MOV

(see Figure 11 on page

28), and buzzer (see Figure 12 on page 29). Replace as necessary.

Replace control panel

fuses.

Yes

Test power switch or adjust so

Replace “ON” light;

that it is actuated properly by

continue on next page.

cam on valve shaft. Replace

 

 

switch as necessary

 

(see Figure 10 on page 27).

 