High-Limit Thermostats Check

SEZ SERIES COUNTERTOP STEAMERS

TROUBLESHOOTING

Figure 18

High-Limit Thermostats Check

1.Note: Allow cavity bottom to cool before performing this test.

2.Disconnect left thermostat lead wire from NO position of R1 relay.

3.Disconnect right thermostat lead wire from wire B58.

4.Disconnect remaining thermostat lead wires from each other.

5.Test each thermostat for continuity. Replace as necessary.

6.Reconnect all thermostat lead wires.