Southbend SEZ-5, SEZ-3 Controller Check, Troubleshooting, Disconnect Power At Circuit Breaker

Models: SEZ-3 SEZ-5

1 48
Download 48 pages 41.95 Kb
Page 32
Image 32
Controller Check

TROUBLESHOOTING

TROUBLESHOOTING

SEZ SERIES COUNTERTOP STEAMERS

Figure 15

Controller Check

Jumper Wire

Terminal Block

Controller

1.DISCONNECT POWER AT CIRCUIT BREAKER.

2.Remove control panel, but leave plugged in.

3.Disconnect wires C98 and C99 from terminals 7 and 9 on the controller. Place a jumper wire between these two terminals.

4.Reconnect power. Turn unit on. WAIT 9 MINUTES.

5.Place test leads between terminal 5 of controller and terminal block position 6, as shown.

6.Use a spacer to hold door switch in closed position and simultaneously check voltage. Voltage should match serial plate voltage for 60 seconds, then drop.

7.If controller fails these tests, replace controller.