Float Switch Continuity Check

SEZ SERIES COUNTERTOP STEAMERS

TROUBLESHOOTING

Figure 14

Float Switch Continuity Check

Pressure Switch

Float Box Lid

Float Switch

Air Vent

1.DISCONNECT POWER AT CIRCUIT BREAKER.

2.Remove rear cover from unit.

3.Disconnect float switch lead wires from wires B40 and B42.

4.Disconnect wires B73 and B74 from the pressure switch.

5.Remove lid from float box.

6.Make sure float travels freely along stem of float switch.

7.Place test leads in float switch terminals as shown.

8.Hold lid in same orientation as when installed.

9.Check continuity. There should be continuity. Replace as necessary.

10.Flip lid over.

11.Check for continuity. There should be no continuity. Replace as necessary.