Southbend SEZ-3, SEZ-5 manual Electric Connection, Installation

Models: SEZ-3 SEZ-5

1 48
Download 48 pages 41.95 Kb
Page 9
Image 9
Step 3: Electric Connection

SEZ SERIES COUNTERTOP STEAMERS

INSTALLATION

Step 3: Electric Connection

A field connection Fuse Block is located at the rear of the unit, lower left side when facing the back of the unit (see Figure 4 below). A hole is provided for a 3/4" conduit fitting (solid or flex). The rear cover must be removed to gain access to fuse block (see Figure 9 on page 26).

Be sure that the input voltage matches the requirement on the serial plate. The unit is factory wired per customer order.

!WARNING

A POSITIVE GROUND CONNECTION IS ESSENTIAL. DO NOT ALLOW ANY TAMPERING OR ADJUSTMENT OF ANY CONTROL OR WIRING. THE UNIT IS FACTORY SET. ADJUSTING ANY INTERNAL COMPONENT OTHER THAN THE MAIN FUSE BLOCK CAN VOID THE WARRANTY.

THIS UNIT REQUIRES A KIT TO BE FIELD CONVERTED FROM THREE-PHASE TO SINGLE- PHASE OR VICE-VERSA. CONSULT FACTORY FOR PHASE CHANGES.

All 208-220-240 and 480 volt units will have three fuse block sections, “L1-L2-L3”, for use with either 3-wire 3-phase or 2-wire, single-phase, 50 or 60 Hz.

Figure 4

 

 

Water Inlet

 

REAR VIEW

Electric Connection

Water Drain

OPERATORS MANUAL 1181587

PAGE 9

INSTALLATION

Page 9
Image 9
Southbend SEZ-3, SEZ-5 manual Electric Connection, Installation