TROUBLESHOOTING
TROUBLESHOOTING | SEZ SERIES COUNTERTOP STEAMERS |
Figure 17
Pressure Switch Check
Pressure Switch
Float Box Lid
Float Switch
Air Vent
1.DISCONNECT POWER AT CIRCUIT BREAKER.
2.Remove rear cover.
3.Remove wires B73 and B74 from pressure switch “COM” and “NO” terminals.
4.Open door.
5.Place test leads on “COM” and “NO” terminals as shown.
6.Check continuity. There should NOT be continuity. Replace as necessary.
7.Remove pressure switch from lid.
8.With test leads on “COM” and “NO” terminals as before, gently blow into pressure port and check continuity. There SHOULD be continuity. Replace as necessary.
PAGE 34 | OPERATOR’S MANUAL 1181587 |