Southbend SEZ-5, SEZ-3 manual Door Switch Continuity Check, Troubleshooting

Models: SEZ-3 SEZ-5

1 48
Download 48 pages 41.95 Kb
Page 30
Image 30
Door Switch Continuity Check

TROUBLESHOOTING

TROUBLESHOOTING

SEZ SERIES COUNTERTOP STEAMERS

Figure 13

Door Switch Continuity Check

Door Switch

9

6

5

4

3

2

1

8

5 Manual background 7

1 2 3

Terminal Block

Controller

1.DISCONNECT POWER AT CIRCUIT BREAKER.

2.Remove control panel.

3.Depress and release door switch actuator rod to make sure door switch is properly actuated.

4.Remove door switch lead wires from terminal block position 1 and terminal 8 of the controller.

5.Place test leads as shown inside the terminal connectors of the lead wires.

6.Check for continuity - (there should be NO continuity).

7.Depress door switch actuator rod and check for continuity - (there should be continuity).

8.Replace as necessary.

PAGE 30

OPERATORS MANUAL 1181587

Page 30
Image 30
Southbend SEZ-5, SEZ-3 manual Door Switch Continuity Check, Troubleshooting, Disconnect Power At Circuit Breaker