Southbend SEZ-3 Inlet Float Valve Check, Troubleshooting, Disconnect Power At Circuit Breaker

Models: SEZ-3 SEZ-5

1 48
Download 48 pages 41.95 Kb
Page 33
Image 33
Inlet Float Valve Check

SEZ SERIES COUNTERTOP STEAMERS

TROUBLESHOOTING

Figure 16

Inlet Float Valve Check

Bushing Seat

Sealing Ball

Float

Bushing Seat Pivot Pin

1.DISCONNECT POWER AT CIRCUIT BREAKER.

2.Remove rear cover.

3.Loosen water inlet compression fitting and rotate water inlet assembly out of the way.

4.Remove lid from float box.

5.Remove 1/8" pipe plug from the rear of the box on the left side (facing unit from rear).

6.Check inlet float valve mechanism (on left side facing unit from rear) for proper actuation.

7.Slide pin out of assembly through hole created by removal of the pipe plug.

8.Inspect sealing ball and bushing seat for debris and deposits.

9.Ensure that float has no leaks or deposits that would prevent it from floating properly.

10.Clean all parts in a container of descaling solution, or replace as necessary.

11.Reassemble all parts.

NOTICE

If the entire float valve assembly is replaced, new Teflon washers must be used and silicone must be used on the bushing seat threads and under the hex head.

TROUBLESHOOTING

OPERATORS MANUAL 1181587

PAGE 33

Page 33
Image 33
Southbend SEZ-3, SEZ-5 manual Inlet Float Valve Check, Troubleshooting, Disconnect Power At Circuit Breaker