SSI America 7SL instruction manual Default Configuration Parameter List

Models: 7SL

1 36
Download 36 pages 19.88 Kb
Page 25
Image 25

d)Still holding the key, press the key; the display will show:

e)Press the key to select Table 1 (European) or Table 2 (American) default parameters; the display will show:

f) Press the FUNC key; the display will show:

This indicates that the loading procedure has been initiated. After about 3 seconds the procedure is com- plete and the instrument reverts to the “COnF” display. The following is a list of the default configuration param- eters loaded during the procedure:

Default Configuration Parameter List

PARA.

Table 1

Table 2

 

European

American

L1

nbUS

nbus

L2

1

1

L3

19200

19200

L4

8E

8E

r1

Type J

Type J

 

(-100 to 1000 °C)

(-150 to 1830 °F)

 

 

 

r2

——.

——.

 

 

 

r3

-100

-150

r4

1000

1830

r5

0

0

 

 

 

r6

1 second

1 second

r7

uP

uP

c1

Hi

Hi

c2

1

0

c3

Auto

Auto

c4

0

0

c5

1 second

1 second

P1

nonE

nonE

P2

H.A.

H.A.Ac

P3

rEV

rEV

P4

OFF

OFF

PF

1 second

1 second

n1

0

0

t1

10 seconds

30 seconds

2 5